Specification
(EIA unit)
2
Heat output (W)
116 W
Power consumption (VA)
126 VA
Air flow (m
3
/min)
3
2.2 (m
3
/min)
Notes:
1. The start-up time might be longer in proportion to the number of drive trays
connected. With a maximum configuration 1 controller chassis and 19 drive trays,
start-up time is approximately 8 minutes.
2. Can be mounted on the RKU rack. For the mounting, special rails for the rack and
decoration panels are required separately depending on the number of the
mounted storage systems.
3. The value is at maximum level.
Drive type
Item
Specification
Supported data
capacity
472.61, 945.23, 1890.46, 3780.92, 7561.85, 15048.49,
30095.00 GB
Maximum storage
system capacity
(physical capacity)
3,941 TiB (using 15 TB 2.5-inch SFF SSD)
7,882 TiB (using 30 TB SSD)
Maximum mountable
quantity (unit)
1
24 (total per chassis)
288 (maximum per system)
Maximum number of
spare drives
2
24
Note:
1. When mounting storage system and DBS/DBSE drive trays, the maximum
mountable quantity (unit) may vary.
2. Available as spare or data disks.
Host interface
Item
Specification
Interface type
16/32 Gbps FC (Optical)