![background image](http://html.mh-extra.com/html/hitachi/ux-twin-nozzle/ux-twin-nozzle_instruction-manual_143809039.webp)
37
4.5 Detail of Data configuration
(1) Details of Analysis information
When an error occurs in the external communication being conducted, the error cause can be
obtained from the analysis information of IJ printer status available at Input Registers.
Analysis information 1 (Function Code): Functional code of the communication message
which resulted in error.
Analysis information 2 (Classification code): Functional classification of the communication
message which resulted in error.
Analysis information 3 (Error factor): Cause which resulted in error.
Analysis information 4 (Preparation for future): Reserved area for future use. 0x0000 fixed.
Code table of Analysis information
No.
item
code
Content
1
Analysis information 1
(Function code)
0x0010
Write on Holding Register
0x0006
Write one word on Holding Register
0x0003 Read
Holding
Register
0x0004
Read Input Register
Other than
the above
Function code which is NOT available
2
Analysis information 2
(Classification code)
0x0000
No classification assigned
0x0001 Index
0x0002 Print
description
0x0003
Delete of Print contents
0x0004
Print data Recall
0x0005
Print data Register
0x0006 Print
format
0x0007 Print
specification
0x0008 Calendar
conditions
0x0009 Substitution
rules.
0x000A Time
count
0x000B Shift
code
0x000C Count
conditions
0x000D Various
setup
0x000E Online/Offline
0x000F Remote
operation
0x0010 Time
control
0x0011
User environment setup (Preparation for future)
0x0012
Touch screen setup
0x0014 Operation
management
0x0015 Circulation
control
0x0016
Print data management
0x0017 Group
control
0x0018
Editing Substitution rules
0x001A
Print job control (Preparation for future)
0x001B
User pattern (Fixed size)
0x001C
User pattern (Free size)
3
Analysis information 3
(Error factor)
0x0001
Invalid Function code
0x0002 Invalid
Address
0x0003
Invalid Data size
0x0004
Invalid CRC code
0x0005 Invalid
Offline
0x0006
Invalid Message repeat print
0x0007
Communication is NOT allowed when Ink ejection is stopped.
0x0010 Invalid
data
4
Analysis information 4
(Preparation for future)
0x0000 0x0000
fixed.