21
Holding Register data configuration (7/13)
Word
address
Classification
Item name
Setting range
Contents
1C E0
Shift code
setup
Start hour
0 to 23
Sets the start time of the shift code
rule 1.
1C E1
Start minute
0 to 59
1C E2
End hour
0 to 23
Sets the end time of the shift code
rule 1.
1C E3
End minute
0 to 59
1C E4
Shift code character
(1st digit)
0x0020 to 0xFFFF
Sets the shift code character of the
shift code rule 1.
…
…
…
1C ED
Shift code character
(10th digit)
0x0020 to 0xFFFF
1C EE Reserve_1
-
"Reserve" is not initially provided,
but may be added in future.
1C EF Reserve_2
1C F0
Shift code rule (Rule 2)
-
Shift code 2 through 48 will be set
in the same configuration as those
of Shift code 1 (Address: from
0x1CE0
~
0x1CEF).
1C FF
…
…
1F D0
Shift code rule (Rule 48)
1F DF
1F E0
Count
condition
Value(1st digit)
0x0020 to 0xFFFF
Sets the value of the count block 1.
…
…
…
1F F3
Value(20th digit)
0x0020 to 0xFFFF
1F F4
Range (Lower limit)
(1st digit)
0x0020 to 0xFFFF
Sets the range (Lower limit) of the
count block 1.
…
…
…
20
07
Range (Lower limit)
(20th digit)
0x0020 to 0xFFFF
20
08
Range (Upper limit)
(1st digit)
0x0020 to 0xFFFF
Sets the range (Upper limit) of the
count block 1.
…
…
…
20 1B
Range (Upper limit)
(20th digit)
0x0020 to 0xFFFF
20 1C
Update (In progress)
0 to 999998
Sets the update (In progress) of
the count block 1.
20 1D
20 1E
Update (Units)
1 to 999999
Sets the update (Units) of the
count block 1.
20
1F
20
20
Increment
1 to 99
Sets the increment of the count
block 1.
20
21
Direction
0 , 1
Sets the direction of the count
block 1.
0:up, 1:down
20
22
Jump (from) (1st digit) 0x0020 to 0xFFFF
Sets the jump (from) of the count
block 1.
…
…
…
20
35
Jump (from) (20th digit) 0x0020 to 0xFFFF
20
36
Jump (to) (1st digit) 0x0020 to 0xFFFF
Sets the jump (to) of the count
block 1.
…
…
…
20
49
Jump (to) (20th digit) 0x0020 to 0xFFFF
20 4A
Reset (1st digit) 0x0020 to 0xFFFF
Sets the reset of the count block 1.
…
…
…
20 5D
Reset (20th digit) 0x0020 to 0xFFFF
20 5E
Reset signal
(Function item for SOP-05)
0 to 2
Sets the reset signal of the count
block 1.
0:Disable , 1:Signal 1 , 2:Signal 2
20
5F
External signal count
(Function item for SOP-05)
0 , 1
Sets the external signal count of
the count block 1.
0:Disable , 1:Enable