(3) When you set Print contents of Item 101 of Nozzle 2 to “Year, Month and Day” of Calendar
characters:
Step 1. Write “Start” on Start/Stop control flag by Holding Register writing.
Step 2. Write “3” on Character count of Item 101 of Nozzle 2 by Holding Register writing.
Step 3. Write “Year, Month and Day” of Calendar characters on Print contents of Item 101 of
Nozzle 2 by Holding Register writing.
Step 4. Write “Stop” on Start/Stop control flag by Holding Register writing.
Holding Register writing request
Holding Register writing response
Reflection in progress
1 Write “Start” on Start/Stop control flag by Holding Register writing. (function code: 0x10).
[Request message data of Holding Register writing]
0000 0000 0009 01 10 0000 0001 02 0001
[Response message data of Holding Register writing]
0000 0000 0006 01 10 0000 0001
(Hexadecimal notation)
Holding Register writing request
Holding Register writing response
2 Write “3” on Character count of Item 101 of Nozzle 2 by Holding Register writing.
(function code: 0x10).
[Request message data of Holding Register writing]
0000 0000 0009 02 10 0020 0001 02 0003
[Response message data of Holding Register writing]
0000 0000 0006 02 10 0020 0001
(Hexadecimal notation)
Holding Register writing request
Holding Register writing response
3 Write “Year, Month and Day” of Calendar characters on the print contents of Item 101 of
Nozzle 2 by Holding Register writing. (function code: 0x10).
[Request message data of Holding Register writing]
0000 0000 0013 02 10 0084 0006 0C F260 0000 F251 0000 F272 0000
[Response message data of Holding Register writing]
0000 0000 0006 02 10 0084 0006
(Hexadecimal notation)
Holding Register writing request
Holding Register writing response
4 Write “Stop” on Start/Stop control flag by Holding Register writing. (function code: 0x10).
[Request message data of Holding Register writing]
0000 0000 0009 01 10 0000 0001 02 0002
[Response message data of Holding Register writing]
0000 0000 0006 01 10 0000 0001
(Hexadecimal notation)
External unit
IJ Printer