– 83 –
HOW TO CHANGE THE SHIFT VALUE for SETTING TEMPERATURE
1. While pressing ON-Timer button, press RESET button at one time.
Stop pressing RESET button only and make sure that all marks on the LCD display are indicated,
then stop pressing the ON-Timer button. (Enters "Shift Value Change Mode".)
2. Press FUNCTION selector button to select FAN mode.
The shift value for setting temperature of COOLING or HEATING operation can be changed with
the remote controller. (This procedure should be done only by service personnel.)
It is possible to reduce or increase in 3 degrees from the initial setting value.
(SHIFTC and SHIFTW : ref. page 24)
PROCEDURE
3. Press the START/STOP button. (The FAN operation will be started.)
Please check the transmission sign and a beep.
COOLING is indicated.
HEATING is indicated.
NOTE :
(1) The indication of the changed shift value and symbol of COOLING or HEATING will disappear
after 10 seconds.
(2) The changed shift value will remain unchanged after turned off the power.
(3) When "0" is indicated, the shift value is at the initial setting.
5. Press START/STOP button to complete the shift value changing procedure.
PROCEDURE 1
PROCEDURE 2
RESET button
ON Timer button
FUNCTION selector
4. Select the following FAN speed to choose required operation mode to change.
- To change the shift value of COOLING operation, select HI or MED of FAN speed.
- To change the shift value of HEATING operation, select LOW or SILENT of FAN speed.
Then Press the TEMPERATURE button to change the shift value.
(The shift value is changed with a beep.)
Reduce 1 deg.
from the value
The initial
setting value
Increase 3 deg.
from the value
Reduce 2 deg.
from the value
Reduce 3 deg.
from the value
RAS_AW_083-093e
2008.03.07, 17:42
83
Summary of Contents for Summit RAC-18YH6
Page 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 18FH6 RAS 25FH6 INDOOR UNIT ...
Page 18: ... 16 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC 18YH6 RAC 25YH6 OUTDOOR UNIT ...
Page 22: ... 20 CIRCUIT DIAGRAM MODEL RAS 18FH6 RAS 25FH6 RAS_AW_020 021_A2 2008 02 18 10 17 20 ...
Page 23: ... 21 RAC 18YH6 RAC 25YH6 MODEL RAS_AW_020 021_A2 11 17 06 11 18 AM 21 ...
Page 24: ... 22 RAS_AW_022_A3e 2008 02 19 16 33 22 ...
Page 25: ... 23 Silent RAS_AW_023_A3e 2008 03 06 20 58 23 ...
Page 27: ... 25 ...
Page 28: ... 26 ...
Page 30: ... 28 ...
Page 31: ... 29 ...
Page 47: ... 45 ...
Page 48: ... 46 ...
Page 50: ... 48 ...
Page 51: ... 49 ...
Page 52: ... 50 ...
Page 54: ... 52 ...
Page 77: ... 75 ...
Page 81: ... 79 ...
Page 82: ... 80 ...
Page 83: ... 81 ...
Page 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 18FH6 RAS 25FH6 ...
Page 96: ...HITACHI AW NO 0024E RAS 18FH6 RAC 18YH6 RAS 25FH6 RAC 25YH6 ...