– 13 –
RAS_AW_001-014en
2008.1.29, 9:39
13
–
18
–
INFORMA
TION
CAP
ABILITIES
Heating Capability
•
This room air conditioner utiliz
es a heat pump system that absorbs
e
xter
ior heat and br
ings it into a room to be heated.
As the ambient
temper
ature gets lo
w
er
, heating capability will also lo
w
er
. In such a
situation, the inverter work to increase compressor rpm to keep the
unit
’s heating capability from decreasing.
If the unit
’s heating perf
or-
mance is still unsatisf
actor
y, other heating appliances should be used
to augment this unit
’s perf
or
mance
.
•
The air conditioner is designed to heat an entire room so that it may take some time before you feel warm.
Timer oper
ation is recommended f
or eff
ectiv
e preheating ahead of the desired time
.
Cooling and Dehumidifying Capabilities
•
If the heat present in a room e
xceeds the unit
’s cooling capacity (f
or e
xample
, if there are man
y people in
the room or other heating appliances are used), the preset room temper
ature ma
y not be reached.
CA
UTION
Do not use a sto
v
e
or an
y other
hightemper
ature
de
vices in pro
ximity
to the indoor unit.
•
When f
an speed, room temper
ature are set with the remote controller bef
ore star
ting man
ual oper
ation and
the b
uttons are released, the indication of settings will go off in 10 seconds and only the operation mode
will be displa
y
ed.
•
Pressing the
b
utton while the unit is in oper
ation will let the protectiv
e circuit w
or
k so that the unit will
not oper
ate f
or appro
ximately 3 min
utes
.
•
Dur
ing heating oper
ation, the indoor unit
’s color indicator lamp ma
y flash with no air emitted f
or a while
.
•
If y
ou f
eel cold wind dur
ing heating oper
ation with the
(HI) f
an speed or w
ant to mak
e the unit oper
ation
quieter after the room is heated, use of
(A
UT
O) setting is recommended.
•
With the
(LO
W),
(SILENT) settings
, the unit
’s cooling capacity will lo
wer slightly
.
•
With the
(LO
W),
(SILENT) settings
, the unit
’s f
an speed of heating oper
ation will v
ar
y with the
oper
ating conditions
.
V
ARIOUS FUNCTIONS
•
When the timer has been prog
rammed, the unit will not oper
ate e
v
en if the set time is reached unless the
unit receiv
es a signal from the remote controller
. Confir
m that timer prog
ramming is complete (beep) and
the
TIMER lamp of the indoor unit lights
.
•
If the
(SLEEP) b
utton is pressed while the ON/OFF timer is prog
rammed, the sleep timer tak
es pr
ior
ity
.
•
Dur
ing sleep timer oper
ation, the f
an speed sets to
(SILENT) regardless of the preset speed.
The
remote controller displa
y indication will remain unchanged e
v
en with the
(SILENT) setting.
TIMER PR
OGRAMMING/SLEEP
TIMER OPERA
TION
PROHIBITION
–
19
–
REGULAR INSPECTION
PLEASE CHECK
THE FOLLO
WING POINTS EVER
Y EITHER HALF
YEARL
Y OR
YEARL
Y
. CONT
A
CT
Y
OUR SALES A
GENT SHOULD
Y
OU NEED ANY HELP
.
1
2
3
W
ARNING
W
ARNING
Chec
k to see if the unit
’s ear
th line has been con-
nected correctl
y
.
If the ear
th line is disconnected or f
aulty
, unit f
ailure or
electr
ic shoc
k hazard ma
y result.
Chec
k to see if the mounting frame has rusted e
x-
cessivel
y or if the outdoor unit has tilted or become
unstab
le
.
It could collapse or f
all, causing injur
y.
AFTER SALES SERVICE AND W
ARRANTY
WHEN ASKING FOR SER
VICE,
CHECK
THE FOLLO
WING POINTS.
CONDITION
CHECK
THE FOLLO
WING POINTS
•
Do the batter
ies need replacement?
•
Is the polar
ity of the inser
ted batter
ies correct?
•
Is the fuse all r
ight?
•
Is the v
oltage e
xtremely high or lo
w?
•
Is the circuit breaker
“ON
”?
•
Is the power plug inserted?
•
Do y
ou ha
v
e an
y po
w
er cut?
•
Is the air filter b
loc
k
ed with dust?
•
Is the set temper
ature suitab
le?
•
Have horizontal air deflectors been adjusted to their correct
positions according to the operation mode selected?
•
Are the air inlets or air outlets of indoor and outdoor units
b
loc
k
ed?
•
Is the f
an speed
“LO
W
”or
“SILENT
”?
When it does not oper
ate
.
When it does not cool w
ell.
When it does not heat w
ell.
If the remote controller is not
tr
ansmitting a signal.
(Remote controller displa
y is
dim or b
lank.)
■
The f
ollo
wing phenomena do not indicate unit f
ailure
.
<Operation start>
The unit is prepar
ing to b
lo
w w
ar
m air
. Please w
ait.
<In operation>
The outdoor unit is defrosting. Please wait.
Refrigerant flow noise in the pipe or valve sound generated when flow rate is
adjusted.
Noise generated when the unit expands or contracts due to temperature changes.
Noise gener
ated with the indoor unit f
an
’s r
pm changing such as oper
ation star
t
times.
Noise of the motorized valve when the unit is switched on.
Dur
ing heating, the oper
ation
indicator b
links and air b
lo
w stops
Hissing or fizzy sounds
Squeaking noise
Rustling noise
W
ARNING
Clicking noise
Chec
k to see if the po
wer plug is securel
y inser
ted
into the wall soc
ket.
If the power plug is not inserted into the wall socket
securely or becomes hot, an electric shock or fire may result.
If dust or dirt is found on the power plug, clean the plug
and insert it into the wall socket.
Summary of Contents for Summit RAC-18YH6
Page 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 18FH6 RAS 25FH6 INDOOR UNIT ...
Page 18: ... 16 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC 18YH6 RAC 25YH6 OUTDOOR UNIT ...
Page 22: ... 20 CIRCUIT DIAGRAM MODEL RAS 18FH6 RAS 25FH6 RAS_AW_020 021_A2 2008 02 18 10 17 20 ...
Page 23: ... 21 RAC 18YH6 RAC 25YH6 MODEL RAS_AW_020 021_A2 11 17 06 11 18 AM 21 ...
Page 24: ... 22 RAS_AW_022_A3e 2008 02 19 16 33 22 ...
Page 25: ... 23 Silent RAS_AW_023_A3e 2008 03 06 20 58 23 ...
Page 27: ... 25 ...
Page 28: ... 26 ...
Page 30: ... 28 ...
Page 31: ... 29 ...
Page 47: ... 45 ...
Page 48: ... 46 ...
Page 50: ... 48 ...
Page 51: ... 49 ...
Page 52: ... 50 ...
Page 54: ... 52 ...
Page 77: ... 75 ...
Page 81: ... 79 ...
Page 82: ... 80 ...
Page 83: ... 81 ...
Page 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 18FH6 RAS 25FH6 ...
Page 96: ...HITACHI AW NO 0024E RAS 18FH6 RAC 18YH6 RAS 25FH6 RAC 25YH6 ...