– 62 –
OTHERS
Q18
A18
Q19
A19
Q20
A20
Q21
A21
Q22
A22
The indoor fan varies among
high air flow, low air flow and
breeze in the auto fan speed
mode. (Heating operation)
This is because the cool
wind prevention function
is operating, and does
not indicate a fault.
The heat exchanger temperature
is sensed in the auto speed mode.
When the temperature is low, the
fan speed varies among high air
flow, low air flow and breeze.
Loud noise from the outdoor unit is
When the “Sleep” timer is set during
operation,
(1) The indoor fan won’t rotate.
(No air comes from the unit)
(2) The air speed won’t change.
The preset temperature is not
indicated on the remote control.
(1) The temperature arrives at the preset indoor
temperature and the air conditioner unit is
temporarily stopped. Within about 3 minutes,
the fan starts rotation.
(2) When the unit operates at “LOW” air speed,
it continues to operate at the same speed.
When automatic operation is performed, the
preset temperature won’t be indicated.
However, you can adjust the temperature within
a range of
±
3
°
C by pressing the “Room
Temperature” button.
If the temperature is 1
°
C higher than the auto
preset temperature, 1
°
C will appear.
If the temperature is 1
°
C lower than the auto
preset temperature, 1
°
C will appear.
heard when operation is started.
When operation is started, the compressor
rotation speed goes to maximum to increase the
heating or cooling capability, so noise becomes
slightly louder. This does not indicate a fault.
Noise from the outdoor unit
occasionally changes.
The compressor rotation speed changes according to
the difference between the thermostat set temperature
and room temperature. This does not indicate a fault.
There is a difference between the set
temperature and room temperature.
There may be a difference between the set
temperature and room temperature because of
construction of room, air current, etc. Set the
temperature at a comfortable for the space.
Air does not flow immediately
after operation is started.
Preliminary operation is performed for one
minute when the power switch on and heating
or dehumidifying is set. The operation lamp
blinks during this time for heating. This does
not indicate a fault.
Q16
A16
Q17
A17
Summary of Contents for Summit RAC-18YH6
Page 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 18FH6 RAS 25FH6 INDOOR UNIT ...
Page 18: ... 16 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC 18YH6 RAC 25YH6 OUTDOOR UNIT ...
Page 22: ... 20 CIRCUIT DIAGRAM MODEL RAS 18FH6 RAS 25FH6 RAS_AW_020 021_A2 2008 02 18 10 17 20 ...
Page 23: ... 21 RAC 18YH6 RAC 25YH6 MODEL RAS_AW_020 021_A2 11 17 06 11 18 AM 21 ...
Page 24: ... 22 RAS_AW_022_A3e 2008 02 19 16 33 22 ...
Page 25: ... 23 Silent RAS_AW_023_A3e 2008 03 06 20 58 23 ...
Page 27: ... 25 ...
Page 28: ... 26 ...
Page 30: ... 28 ...
Page 31: ... 29 ...
Page 47: ... 45 ...
Page 48: ... 46 ...
Page 50: ... 48 ...
Page 51: ... 49 ...
Page 52: ... 50 ...
Page 54: ... 52 ...
Page 77: ... 75 ...
Page 81: ... 79 ...
Page 82: ... 80 ...
Page 83: ... 81 ...
Page 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 18FH6 RAS 25FH6 ...
Page 96: ...HITACHI AW NO 0024E RAS 18FH6 RAC 18YH6 RAS 25FH6 RAC 25YH6 ...