3-4. Error Message comparison
Digital Panel
DOP / DRW
Contents
OC. Drive
Over current while constant speed
driving (CT or gate driver IC)
OC. Decel
Over current while deceleration (CT or
gate driver IC)
OC. Accel
Over current while acceleration (CT or
gate driver IC)
Over. C
Over current at other condition than
above(such as 0Hz,injection brake)
(CT or gate driver IC)
Over. L
Over load
(Possible to reset after 10 seconds
has passed, detected by CT)
OL. BRD
Over voltage after the BRD%ED
was run out. (DC bus)
Over. V
Over voltage (DC bus)
EEPROM
EEPROM error
(Check the parameters again if this
error occurred)
Under. V
Under voltage (DC bus)
CT
CT offset error such as external noise
or CT itself
CPU 1
CPU error
CPU 2
External
External error
USP
USP error
GND Flt
Ground fault at power-on detected by
CT
OV. SRC
Over voltage at source (DC bus)
(continuously 100sec while stop)
OH FIN
Over temperature (in the ISPM)
PTC
PTC error (only terminal 5 )