CHAPTER5 OPERATING
19
5.5 Profidrive specific parameters
The table below shows which Profidrive specific parameters that are supported by the SJ-PB(T).
Table 5-1 Profidrive parameters
PNU -
Parameter Number
Description
Range
915
Assignment of PZD write word
3-10
Refer to chapter 5.3.3 and 5.4.3 for how to assign PZD
words. Use the parameter cross-reference list in
chapter 5.
Please note:
Parameters will be lost when turning
power off unless parameter 971 has been written with
“0->1”.
Parameter range:
1 – 418.
Sub-index range:
1 – 8.
R/W
916
Assignment of PZD read word
3-10
Refer to chapter 5.3.3 and 5.4.2 for how to assign PZD
words. Use the parameter cross-reference list in
chapter 5.
Please note:
Parameters will be lost when turning
power off unless parameter 971 has been written with
“0->1”.
Parameter range:
1 – 418.
Sub-index range:
1 – 8.
R/W
918
Profibus-DP slave address
Returns address switch setting.
1-99
R
927
Parameter edit rights
1 – PKW interface enabled. Parameters can be
read/written.
0 – PKW interface disabled, only parameter 927 can
be read/written.
0, 1
R/W
928
Control rights (process data).
1 – Option board will send control word, reference and
will update PZD3-10.
0 – PZD not enabled.
0, 1
R/W
947
Indexed Fault memory
Fault. Codes as described in table 5-2 below.
Sub-index 1 = Not acknowledged fault.
Sub-index 9 = Latest acknowledged fault.
Sub-index 17 = 2
nd
latest acknowledged fault.
Sub-index 25 = 3
rd
latest acknowledged fault.
Sub-index 33 = 4
th
latest acknowledged fault.
Sub-index 41 = 5
th
latest acknowledged fault.
Sub-index 49 = 6
th
latest acknowledged fault.
-
R
963
PROFIBUS-DP baud rate
the baudrate of the Profibus-DP network
0: 12 Mbit/s 1: 6 Mbit/s 2: 3 Mbit/s 3: 1.5 Mbit/s
4: 500 kbit/s 5: 187.5 kbit/s 6: 93.75 kbit/s
7: 45.45 kbit/s 8: 19.2 kbit/s 9: 9.6 kbit/s
0-9
R
964
Device identification
Bit 15 represents the type of inverter, 0 – SJxxx, 1 –
LxxxP. Rest of the word represents the model number.
SJ300 - 0x012C
L300P - 0x812C
012Ch, 812Ch
R
965
Profile version
Returns the Profidrive profile version used in the SJ-PB
implementation
2
R
967
Control Word
Shows the latest received control word in hex format
Refer to chapter 5.3.1 for detailed information about
the control word.
Bit 0-15
R
968
Status Word
Shows the latest status word in hex format
Refer to chapter 5.3.1 for detailed information about
the status word.
Bit 0-15
R
971
Transfer into non-volatile
memory
Please note that it will take approximately 10s for this
process to finish (inverter must be stopped).
0 – No function.
1 – Will save inverter parameters to non-volatile
memory and the Profile specific parameters to FLASH.
0, 1
W