APPENDIX PARAMETER CROSS-REFERENCE LIST
26
Code No. Size
Range
Magn.
Contents
L300P
Read/
Write
C088
164
1
0.0
〜
20.0mA
*10
Adjustment of Offset of AMI output
R/W
C091
166
1
00,01
code
Selection of Debug mode method
R/W
C041
168
2
0
〜
200.0(%)
*10
Level1 of overload restriction warning
R/WOS
C111
169
2
0
〜
200.0(%)
*10
Level2 of overload restriction warning
No
R/WOS
C044
170
2
0
〜
100.0%
*10
Level over acceptable deviation of
PID control
R/WOS
C063
171
2
0
〜
100.00Hz
*100
Level f detecting Zero speed
No
R/WOS
C061
173
2
0
〜
100%
*1
Warning Level of
electronic thermal protection
R/WOS
C078
174
2
0
〜
1000ms
*1
Waiting time of communication start
R/WOS
P011
176
2
128
〜
65000pls
*1
Pulse number of the encoder
No
R/WOS
P014
177
2
0
〜
4095
*1
Stop position at Orientation mode
No
R/WOS
P015
178
2
0
〜
120.00Hz
*100
Speed at Orientation mode
No
R/WOS
P017
179
2
0
〜
10000pls
*1
Defining Area of completion of
Orientation mode
No
R/WOS
P018
180
2
0
〜
9.99s
*100
Delay time of completion
Orientation mode
No
R/WOS
P020
181
2
0
〜
9999
*1
The numerator of electric gear
No
R/WOS
P021
182
2
0
〜
9999
*1
The denominator of electric gear
No
R/WOS
P022
183
2
0
〜
655.35
*100
Feed forward gain of position control
No
R/WOS
P023
184
2
0
〜
100.00
*100
Loop gain of position control
No
R/WOS
P026
185
2
0
〜
150.0
*10
Level of detecting over speed
No
R/WOS
P027
186
2
0
〜
120.00Hz
*100
Value of detecting over deviation
No
R/WOS
F004
188
1
00,01
code
Selection of running direction
for DIG-OPE
R/WOS
A001
189
1
00
〜
05
code
Selection of frequency command destination
R/WOS
A002
190
1
01
〜
05
code
Selection of running command destination
R/WOS
A005
191
1
00,01
code
Selection of AT function
R/WOS
A006
192
1
00
〜
02
code
Selection of O2 terminal function
R/WOS
A013
193
1
0
〜
100%
*1
Starting rate of O terminal
R/WOS
A014
194
1
0
〜
100%
*1
End rate of O terminal
R/WOS
A015
195
1
00,01
code
Selection of starting function of O terminal
R/WOS
A016
196
1
1
〜
30times
*1
Analog Sampling
R/WOS
A113
197
1
-100
〜
100%
*1
Starting rate of O2 terminal
R/WOS
A114
198
1
-100
〜
100%
*1
End rate of O2 terminal
R/WOS
A103
199
1
0
〜
100%
*1
Starting rate of OI terminal
R/WOS
A104
200
1
0
〜
100%
*1
End rate of OI terminal
R/WOS
A105
201
1
00,01
code
Selection of starting function of OI terminal
R/WOS
A019
203
1
00,01
code
Selection of Multispeed method
R/WOS
A039
204
1
00
〜
05
code
Selection of Jogging method
R/WOS
A041
205
1
00,01
code
Selection of 1st Torque boost Method
R/WOS
A241
206
1
00,01
code
Selection of 2nd Torque boost Method
R/WOS
A042
207
1
0
〜
20.0%
*10
Value of 1st Manual torque boost
R/W
A242
208
1
0
〜
20.0%
*10
Value of 2nd Manual torque boost
R/W
A342
209
1
0
〜
20.0%
*10
Value of 3rd Manual torque boost
No
R/W
A044
210
1
00
〜
05
code
Selection of 1st Control method
00
〜
02
R/WOS
A244
211
1
00
〜
04
code
Selection of 2nd Control method
00
〜
02
R/WOS
A344
212
1
00,01
code
Selection of 3rd Control method
No
R/WOS