APPENDIX PARAMETER CROSS-REFERENCE LIST
31
Code No. Size
Range
Magn.
Contents
L300P
Read/
Write
d084
376
2
0
〜
1000.0V
*10
PN voltage (DC voltage) of Trip4
RO
d084
377
4
0
〜
4294836225s
*1
Accumulated time during running
of Trip4
RO
d084
378
4
0
〜
4294836225s
*1
Accumulated time during power ON
of Trip4
RO
d085
379
4
00
〜
H'FF
*1
Factor and Status of Trip5
RO
d085
380
4
0
〜
400.00Hz
*100
Frequency of Trip5
RO
d085
381
2
0
〜
1000.0A
*10
Output current of Trip5
RO
d085
382
2
0
〜
1000.0V
*10
PN voltage (DC voltage) of Trip5
RO
d085
383
4
0
〜
4294836225s
*1
Accumulated time during running
of Trip5
RO
d085
384
4
0
〜
4294836225s
*1
Accumulated time during power ON
of Trip5
RO
d086
385
4
00
〜
H'FF
*1
Factor and Status of Trip6
RO
d086
386
4
0
〜
400.00Hz
*100
Frequency of Trip6
RO
d086
387
2
0
〜
1000.0A
*10
Output current of Trip6
RO
d086
388
2
0
〜
1000.0V
*10
PN voltage (DC voltage) of Trip6
RO
d086
389
4
0
〜
4294836225s
*1
Accumulated time during running
of Trip6
RO
d086
390
4
0
〜
4294836225s
*1
Accumulated time during power ON
of Trip6
RO
-
392
1
00
〜
02
code
Selection of Area code of inverter
RO
-
393
1
01
〜
15
code
Selection of Capacity code of inverter
RO
-
394
1
00,01
code
Selection of Voltage of inverter
RO
-
395
1
00,01
code
Selection of Changeover of inverter mode
RO
d001
397
4
0
〜
400.000Hz
*1000
Output frequency
RO
d004
398
4
0
〜
400.000Hz
*1000
Feedback data of PID control
RO
d007
399
4
0
〜
39960.000
*1000
Value of conversion of frequency
RO
d101
400
4
0
〜
400.000Hz
*1000
Output frequency after Vector control
RO
d016
401
4
0
〜
4294836225s
*1
Accumulated time during running
RO
d017
402
4
0
〜
4294836225s
*1
Accumulated time during Power ON
RO
-
403
4
0
〜
400.000Hz
*1000
Setting frequency from terminal
RO
-
404
4
0
〜
400.000Hz
*1000
Setting frequency from
attached potentiometer
RO
-
405
4
0
〜
400.000Hz
*1000
Setting frequency from digital operator
RO
d002
407
2
0
〜
1000.0A
*10
Output current
RO
d005
408
2
0
〜
H'FFFF
bit
Status of Input terminal
RO
d012
409
2
-300
〜
+300%
*1
Output Torque
No
RO
d014
410
2
0
〜
1000.0kW
*10
Input electric power
RO
412
2
0
〜
1000.0V
*10
DC voltage
RO
413
2
0
〜
100.0s
*10
On time of BRD running
RO
414
2
0
〜
100.0%
*10
Used rate of electronics thermal protection
RO
d006
416
2
0
〜
H'FFFF
bit
Status of output terminal
RO
d013
417
2
0
〜
1000.0V
*10
Output voltage
RO
d003
418
1
00
〜
02
code
Direction of present running
RO
R/W: Parameter is read/writable.
R/WOS: Parameter is readable, but can only be written when the inverter is stopped.
R/O: Parameter is read-only. Cannot be written.