APPENDIX PARAMETER OBJECT LISTS
25
Address
Size
Setting
range
magn.
Contents
L300P
operator
code
H'08000170
2 20.0
〜
120.0
*10
Level of 1st Electronic thermal protection
b012
H'08000172
2 20.0
〜
120.0
*10
Level of 2nd Electronic thermal protection
b212
H'08000174
2 20.0
〜
120.0
*10
Level of 3rd Electronic thermal protection
No
b312
H'08000176
2 0
〜
400Hz
*1
Free electronic thermal frequency 1
b015
H'08000178
2 0
〜
1000.0A
*10
Free electronic thermal current 1
b016
H'0800017A
2 0
〜
400Hz
*1
Free electronic thermal frequency 2
b017
H'0800017C
2 0
〜
1000.0A
*10
Free electronic thermal current 2
b018
H'0800017E
2 0
〜
400Hz
*1
Free electronic thermal frequency 3
b019
H'08000180
2 0
〜
1000.0A
*10
Free electronic thermal current 3
b020
H'08000182
2 0
〜
400Hz
*1
Free V/F control frequency 1
b100
H'08000184
2 0.0
〜
800.0V
*10
Free V/F control voltage 1
b101
H'08000186
2 0
〜
400Hz
*1
Free V/F control frequency 2
b102
H'08000188
2 0.0
〜
800.0V
*10
Free V/F control voltage 2
b103
H'0800018A
2 0
〜
400Hz
*1
Free V/F control frequency 3
b104
H'0800018C
2 0.0
〜
800.0V
*10
Free V/F control voltage 3
b105
H'0800018E
2 0
〜
400Hz
*1
Free V/F control frequency 4
b106
H'08000190
2 0.0
〜
800.0V
*10
Free V/F control voltage 4
b107
H'08000192
2 0
〜
400Hz
*1
Free V/F control frequency 5
b108
H'08000194
2 0.0
〜
800.0V
*10
Free V/F control voltage 5
b109
H'08000196
2 0
〜
400Hz
*1
Free V/F control frequency 6
b110
H'08000198
2 0.0
〜
800.0V
*10
Free V/F control voltage 6
b111
H'0800019A
2 0
〜
400Hz
*1
Free V/F control frequency 7
b112
H'0800019C
2 0.0
〜
800.0V
*10
Free V/F control voltage 7
b113
H'0800019E
2 50.0
〜
200.0
*10
Level of Overload restriction 1
50.0
〜
150.0
b022
H'080001A0
2 0.10
〜
30.00
*100
Constant value of Overload restriction 1
b023
H'080001A2
2 50.0
〜
200.0
*10
Level of Overload restriction 2
50.0
〜
150.0
b025
H'080001A4
2 0.10
〜
30.00
*100
Constant value of Overload restriction 2
b026
H'080001A6
2 0
〜
65535(*10hr)
*1/10
Display time of warning
b034
H'080001A8
2 0
〜
1000.0V
*10
Starting voltage of Nonstop operation
for Instantaneous power failure
No
b051
H'080001AA
2 0
〜
1000.0V
*10
Starting voltage of OV-LAD stop at Nonstop
operation for Instantaneous power failure
No
b052
H'080001AC
2 0
〜
10.00Hz
*100
Frequency width of starting deceleration at
Nonstop operation for Instantaneous power failure
No
b054
H'080001AE
2 0.10
〜
9.99Hz
*100
Minimum frequency
b082
H'080001B0
2 0.1
〜
99.9
*10
Coefficient of converting frequency
b086
H'080001B2
2 0
〜
100.0%
*10
Usage rate of BRD
b090
H'080001B4
2 330
〜
380/660
〜
760 *1
On level of BRD
b096
H'080001B6
2 0
〜
9999ohm
*1
Level of Thermister error
b099
H'080001B8
2 0.00
〜
5.00s
*100
Waiting time for establishing external braking
condition
No
b121
H'080001BA
2 0.00
〜
5.00s
*100
Waiting time for acceleration at external braking
No
b122
H'080001BC
2 0.00
〜
5.00s
*100
Waiting time for stop at external braking
No
b123
H'080001BE
2 0.00
〜
5.00s
*100
Waiting time for confirmation signal at external
braking
No
b124
H'080001C0
2 0
〜
400.00Hz
*100
Release frequency of external braking
No
b125
H'080001C2
2 0
〜
200.0(%)
*10
Release current of external braking
No
b126
H'080001C4
14 -
-
Access Inhibited
No
-
H'080001D2
2 0.001
〜
65.535
*1000
1st Speed response gain
No
H005
H'080001D4
2 0.001
〜
65.535
*1000
2nd Speed response gain
No
H205
H'080001D6
2 0
〜
255
*1
1st Stability gain
H006
H'080001D8
2 0
〜
255
*1
2nd Stability gain
H206
H'080001DA
2 0
〜
255
*1
3rd Stability gain
No
H306
H'080001DC
2 0
〜
1000.0(%)
*10
1st Proportional gain of speed control
No
H050