![Hitachi RWM-(H)FSN3E Technical Catalogue Download Page 152](http://html.mh-extra.com/html/hitachi/rwm-h-fsn3e/rwm-h-fsn3e_technical-catalogue_2139430152.webp)
11 Installation
configurations
TCGB0070 rev.3 - 04/2012
152
Installation example 6
Installation with alternating space h Domestic Hot Water Tank + Boiler combination: Space heating application
with optional Room Thermostat and Domestic Hot Water Tank heated by alternating Heat Pump and boiler combination.
Item
Description
1
Outdoor unit
2
Indoor unit
3
Heat exchanger
4
Electrical heater
5
Water pump (primary)
6
Valves (factory supplied)
7
Domestic Hot Water Tank
(DHWT) (accessory)
8
3-way valve for DHWT (acces-
sory)
9
Second temperature kit (acces
-
sory)
11
Boiler (field supplied)
12
Hydraulic separator (accessory)
13
Water pump (field supplied)
14
Hydraulic separator sensor (ac-
cessory)
A
3-way valve output signal
B
DHWT electrical heater signal
C
DHWT sensor signal (accessory)
G
Boiler output signal
H
Water pump 3 signal (WP3)
J
Hydraulic sensor signal (Two3)
(accessory)
R410a
High Tempera-
ture (60ºC)
Low Tempera-
ture (35ºC)
H20
EH
3wv DHWT
Boiler
Boiler
Signal
T
DHWT
DHWT
J Two3
H WP3
Installation example 7
Two space heating applications (High & Low water temperature) + Combination with Boiler in parallel: Two space heating
application with a Room Thermostat as an option and Domestic Hot Water Tank heated by Heat Pump and boiler combi
-
nation in parallel
R410a
High Temperature (60ºC) Low Temperature (35ºC)
H20
Vmix
Boiler
Boiler
Signal
Two2
WP2
J Two3
H
WP3
Item
Description
1
Outdoor unit
2
Indoor unit
3
Heat exchanger
4
Electrical heater
5
Water pump (primary)
6
Valves (factory supplied)
9
Second temperature kit (acces
-
sory)
10
Motorized valve (field supplied)
11
Boiler (field supplied)
12
Hydraulic separator (accessory)
13
Water pump (field supplied)
14
Hydraulic separator sensor (ac-
cessory)
D
2nd Temperature sensor signal
(accessory)
E
Secondary water pump signal
F
Mixing valve signal
G
Boiler output signal
H
Water pump 3 signal (WP3)
J
Hydraulic sensor signal (Two3)
K
Optional signal