Software options
Ordering no
#3
Notes and rules
No option
X00
1)
High impedance differential protection - 3 blocks
1MRK004001-AB
A02
Line differential protection 6 CT sets
1MRK004001-AD
A04
2)
,
3)
Line differential protection 6 CT sets + transformer
1MRK004001-AF
A06
Line differential protection for 3 CT sets, 2-3 line ends
1MRK004001-AU
A34
Phase segregated scheme communication
1MRK004001-XD
B05
Out-of-step protection
1MRK004001-BW
B22
4)
Pole slip protection
1MRK004001-VU
B24
5)
Stub protection
1MRK004001-VK
B27
6)
High speed distance protection, quad and mho characteristic
1MRK004001-XA
B35
4)
Sensitive directional residual overcurrent and power protection
1MRK004001-CT
C16
Scheme communication for residual overcurrent protection
1MRK004001-VN
C34
4)
Directional power and voltage restrained overcurrent protection
1MRK004001-VL
C35
Average power transient earth fault protection
1MRK004001-UY
C54
Overexcitation protection - 2 winding
1MRK004001-DC
D03
Frequency protection - line
1MRK004001-ED
E04
7)
General current and voltage protection
1MRK004001-FA
F01
Fuse failure supervision based on voltage difference
1MRK004001-HC
G03
Autorecloser, 1 circuit breaker
1MRK004001-GD
H04
8)
Autorecloser, 2 circuit breakers
1MRK004001-GE
H05
9)
Control functionality for up to 10 objects
1MRK004001-GW
H37
10)
Control functionality for up to 15 objects
1MRK004001-GY
H38
Through fault monitoring
1MRK004001-KR
M22
Harmonic monitoring
1MRK004001-KS
M23
IEC 62439-3 Parallel redundancy protocol
1MRK004001-PP
P23
11)
IEC 62439-3 High-availability seamless redundancy
1MRK004001-PR
P24
Rapid spanning tree protocol
1MRK004001-PY
P25
IEC 61850-9-2 Process Bus communication, 8 merging units
1MRK004001-PT
P30
Synchrophasor report, 8 phasors
1MRK004001-PV
P32
12)
Selection for
position #3
1)
All fields in the ordering form do not need to be filled in.
2)
Only one Line differential protection has to be selected.
3)
A04, A06 and A34 only for B33
4)
Only for B33/A42/ B42
5)
Only for C42
6)
Only for B33/B42; 1 block included as basic
7)
1 block already included
8)
Only for A42/C42, 1 block already included
9)
Only for B33/B42, 2 blocks already included
10) H37 only for A42/C42, H38 only for B33/B42
11) Options P23, P24 and P25 require two SFPs placed in pairs.
12) This functionality requires accurate time synchronization, therefore either Precision Time Protocol (PTP) Time synch or GTM or IRIG-B will be required.
Language
Ordering no
#4
Notes and rules
First local HMI user dialogue language
HMI language, English IEC
1MRK002930-AA
B1
Additional local HMI user dialogue language
No additional HMI language
X0
HMI language, English US
1MRK002920-UB
A12
1)
Selection for
position #4
B1
1)
Additional 2nd languages are continuously being added. Please get in touch with local Hitachi Power Grids sales contact.
Casing
Ordering no
#5
Notes and rules
1/2 x 19" rack casing, 1 TRM
1MRK000151-VA
A
3/4 x 19" rack casing, 1 TRM
1MRK000151-VB
B
3/4 x 19" rack casing, 2 TRM
1MRK000151-VE
C
1/1 x 19" rack casing, 1 TRM
1MRK000151-VC
D
1/1 x 19" rack casing, 2 TRM
1MRK000151-VD
E
Selection for
position #5
Line differential protection RED670
1MRK 505 379-BEN R
Version 2.2
Hitachi Energy
181
© 2017 - 2022 Hitachi Energy. All rights reserved