– 5 –
SPECIFICATIONS
MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (for MICROPROCESSOR)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
SERVICE SWITCH
TRANSFORMER
VARISTOR
NOISE SUPPRESSOR
THERMOSTAT
REMOTE CONTROL SWITCH (LIQUID CRYSTAL)
40 W
NO
NO
NO
YES
YES
5.0A
G4A
NO
NO
YES
NO
450NR
YES
YES(IC)
NO
1650g
WITHOUT REFRIGERANT BECAUSE
COUPLING IS FLARE TYPE.
UNIT
PIPES
REFRIGERANT CHARGING
VOLUME
(Refrigerant 410A)
RAM-55QH4
RAM-65QH4
JU1013D2
MAX. 35m
MAX. 45m
RAM-65QH4
In case the pipe length is more than 35m, add refrigerant R410 at 20gram per every meter exceeds.
RAM-55QH4
Additional charge of refrigerant is not required.
Summary of Contents for RAM-55QH4
Page 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH4 ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH4 39 L C023 C022 C002 C001 C025 C024 N ...
Page 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH4 41 L C023 C022 C002 C001 C025 C024 N ...
Page 41: ... 45 ...
Page 47: ... 53 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 48: ... 55 ...
Page 49: ... 57 ...
Page 50: ... 59 ...
Page 51: ... 61 ...
Page 69: ... 79 5A ...
Page 76: ... 86 ...
Page 92: ... 105 ...
Page 93: ... 106 ...
Page 99: ... 112 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 100: ... 113 ...
Page 101: ... 114 ...
Page 103: ... 116 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Page 104: ... 117 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH4 MODEL RAM 65QH4 ...
Page 109: ...HITACHI PM NO 0217E Printed in Malaysia RAM 55QH4 RAM 65QH4 ...