– 18 –
Above 100mm
Drain hole
Bushing
Outer diameter above 16mm
b
•
•
•
•
Condensed water disposal of outdoor unit
When Using and Installing in Cold Areas
There is holes on the base of outdoor unit for condensed water to exhaust.
To lead condensed water to the drain hole, place the outdoor unit on the mounting stand (optional) or on blocks to raise its
level more than 100mm from the ground surface. Connect the drain pipe as shown in the figure. Cover two other water
drain holes with the bushings included. (To insall a bushing, push in both ends of the bushing so that it aligns with the drain
hole.)
When connecting the drain pipe, make sure that the bushing does not lift off or deviate from the base.
1. Remove flare nut from service valve.
4. Perform air purge and gas leak inspection.
2. Apply refrigerant oil to flare nut sections of servicevalve and pipings.
5. Wrap the provided insulating material around sidepiping using vinyl tape.
3. Match center of piping to large diameter side service valve and tank assembly, and tighten flarenut first by hand,
then securely tighten using torque wrench.
Install the outdoor unit on a stable, flat surface and check to see that the condensed water drains.
For more details, refer to the Installation Manual for Cold Areas.
When the air conditioner is used in low temperature and in snowy conditions, water from the heat exchanger may freeze
on the base surface to cause poor drainage. When using the air conditioner in such areas, do not install the bushings. Keep a
minimum of 250mm between the drain hole and the ground. When using the drain pipe, consult your sales agent.
Bushing
b
Bushing
b
Drain pipe
Drain hole
Push
Push
a
Summary of Contents for RAM-55QH4
Page 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH4 ...
Page 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH4 39 L C023 C022 C002 C001 C025 C024 N ...
Page 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH4 41 L C023 C022 C002 C001 C025 C024 N ...
Page 41: ... 45 ...
Page 47: ... 53 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Page 48: ... 55 ...
Page 49: ... 57 ...
Page 50: ... 59 ...
Page 51: ... 61 ...
Page 69: ... 79 5A ...
Page 76: ... 86 ...
Page 92: ... 105 ...
Page 93: ... 106 ...
Page 99: ... 112 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Page 100: ... 113 ...
Page 101: ... 114 ...
Page 103: ... 116 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Page 104: ... 117 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH4 MODEL RAM 65QH4 ...
Page 109: ...HITACHI PM NO 0217E Printed in Malaysia RAM 55QH4 RAM 65QH4 ...