LD301 blinks 8 times.
Acceleration error
LD301 blinks 7 times.
Thermistor abnormal.
Is system power module (SPM2)
normal?
Is drive circuit normal?
Is thermistor connected correctly?
Replace system power
module. (SPM2)
Replace defective parts.
Connect thermistor
.
Replace thermistor
.
Replace thermistor circuit
parts.
Looking at P
.W
.B. diagram and
circuit diagram, perform continuity
check of pattern and lead wire.
Looking at P
.W
.B. diagram and
circuit diagram, perform continuity
check of pattern and lead wire.
No
No
Ye
s
❈
Be careful not to forget to connect
it after servicing is completed.
Is continuity of thermistor normal?
Is thermistor circuit normal?