– 68 –
5. Room Temperature Thermistor Circuit
●
Fig. 5-1 shows the room temperature
thermistor circuit.
5
4
3
2
1
0
0
10
Room temperature (ßC)
Fig. 5-2
20
30
40
0V
Room
temperature
thermistor
0V
5V
Fig. 5-1
A
R309
C301
Micro
computer
AX-7M12
Room
temp. input
V
oltage at
(V)
R310
0V
Heat exchanger
temperature thermistor
0V
5V
Fig. 6-1
A
R307
C302
Micro computer
AX-7M12
Heat
exchanger
temperature
input
R308
A
5
4
3
2
1
0
0
10
-10
Heat exchanger temperature (ßC)
Fig. 6-2
20
30
40
V
oltage at
(V)
A
1
64
6. Heat exchanger temperature thermistor circuit
●
The voltage at
A
depends on the room
temperature as shown in Fig. 5-2.
●
The circuit detects the indoor heat
exchanger temperature and controls
the following.
(1)
Preheating.
(2)
Low-temperature defrosting
during cooling and dehumidifying
operation.
(3)
Detection of the reversing valve
non-operation or heat exchanger
temperature thermistor open.
The voltage at
A
depends on the heat
exchanger temperature as shown in
Fig. 6-2.