– 84 –
Drive
signal
Chopper
signal
Chopper
signal
DC
Current
level
AX-6M00
DC current
Detection
resistor
5V
DC330V
or 360V
Reset circuit
Overload external
judgement circuit
Current amplified
circuit
Drive
Circuit
IP signal
Reset Voltage
Peak current
cut off circuit
Outdoor microcomputer
T
rip signal
synthesis circuit
Compressor
motor
Inverter
section
Fig. 7-2
●
The following gives details of operation for each circuit:
7-1. Peak current cut off circuit
Fig.7-3 shows peak current cut off circuit and waveforms at each point.
DC current Id
Voltage at point
1.35V
27A
Voltage at point
A
B
A
—
Fig.7-3
Detection
resistor
Negative
Terminal
DC current
0V
R24
R41
0V
R43
0V
OC
R42
SPM
HIC
Control P.W.B.
IC1
CN14
IP cutter
Outdoor
microcomputer
F
C43
9
9
8
20
9
2
9
B
●
Ip cut circuit detects instantaneous surge current and stops inverter to protect components such as SPM.
●
As shown in diagram, when current exceeding 24A flows, voltage at point
A
detected by detection
resistor is input to pin
9
of INV-HIC, and voltage divided by R41 and R43 is input to pin
9
of IC1. Since
this voltage exceeds threshold of IC1, LO is output from pin
8
(voltage at point
B
). When LO is input
to pin
9
of microcomputer, microcomputer stops drive output.
●
When drive output of microcomputer stops, all drive outputs are set to HI, and IC1 of HIC is initialized
to enter drive signal waiting status. Microcomputer again outputs drive signal 3 minutes later to re-start
operation.
Summary of Contents for RAM-50CNHZ2
Page 41: ... 40 WIRING DIAGRAM MODEL RAM 50CNHZ2 OUTDOOR UNIT ...
Page 47: ... 51 BASIC MODE MODEL RAM 50CNHZ2 ...
Page 50: ... 57 ...
Page 51: ... 59 ...