CHECKING THE OUTDOOR UNIT ELECTRICAL PARTS
MODEL RAM-50CNHZ2
[Air conditioner not operated/not operated correctly]
Is 220-240V supplied to L,N
terminal?
Is 25A fuse normal?
Is power circuit normal?
Refer to item of power circuit
for details.
Is the 5V supplied between
Pin
4
(test pin) and pin
5
(5V) of CN18?
Operate outdoor unit
according to instructions on
“How to operate outdoor unit
independently
”.
How is self-diagnosis lamp
(LD301) lighting?
If fuse is blown, other parts may be
af
fected. T
ake
care.
(Mainly
, varistor 2, diode stack,
smoothing capacitor
, and system
power module.)
Is switching power circuit OK?
Is 3A fuse normal?
Refer to lighting mode of self-
diagnosis lamps.
Replace defective components.
Check to see whether the
connected cord D cable correctly?
If reversed, correct the cable
connection.
Replace defective components.
If 3A fuse is blown, switching
transformer
, could be
defective.
()