See next page
for measuring
value using
multimeter
IPM (Intelligent Power Module) DIAGNOSIS
PS21564-C
Circuit of 1 device
Gate
Collector
Emitter
Internal circuit
diagram of
module
Terminal
symbols of
power module
6
:
PGU
12
:
PGV
18
:
PGW
21
:
NGU
22
:
NGV
23
:
NGW
24
:
Fail signal
31
:
P
32
:
U
33
:
V
34
:
W
35
:
N
NGW
NGV
NGU
PGW
PGV
PGU
P
U
V
W
LIN2
FO
LIN3
HS
HIN
LO3
34
LO1
LIN1
HS
HO
HO
HIN
HIN
HO
33
LO2
HS
32
N
28 26 24 22 20 18 16
12 10
6 4
1
27 25
35
34
33
32
31
N
W
V
U
P
23 21
15 13
9 7
3
24
35
23
22
2
1
18
12
6
3
1
Model
P
U
V
W
U
P
N
V
W
N
Diagnosis procedure for power module using multimeter
[Inverter section]
Set the multimeter to resistance range of
×
100. If
×
100 is not provided, measure with the range of
×
1 to
×
100.
If the pointer does not swing when the following continuity check is performed, it is normal.
(When a digital multimeter is used, + and - terminals will be reversed, since the orientation of built-in
battery is inverted.)
Note:
If internal circuit of power module is disconnected (open) and pointer of the mutimeter does not swing,
it may be assumed to be normal. If the pointer swings when + and - terminals are connected in
reverse, it is normal. Compare swing statuses for U, V and W phases: If the statuses at all 3 points are
the same, it is normal.
- 92 -