HEATING OPERATION
●
Use the device for heating when the outdoor temperature is under 21
°
C.
When it is too warm (over 21
°
C), the heating function may not work in order to protect the device.
●
In order to keep reliability of the device, please use this device above -15
°
C of the outdoor temperature.
Press the FUNCTION selector so that the display indicates
(HEAT).
Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO)
: The fan speed changes automatically
according to the temperature of the air which
blows out.
(HI)
: Economical as the room will become warm
quickly.
But you may feel a chill at the beginning.
(MED)
: Fan speed slow.
(LOW)
: Fan speed slower.
(SILENT) : Fan speed ultra slower.
Set the desired room temperature with the TEMPERATURE
buttons (the display indicates the setting).
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
Press the (START/STOP) button. Heating operation starts
with a beep. Press the button again to stop operation.
■
As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.
1
2
3
START
STOP
■
Defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchange of the outdoor
unit, for 5~10 minutes each time.
During defrosting operation, the operation lamp blinks in cycle of 3 seconds on and 0.5 second off.
The maximum time for defrosting is 20 minutes.
However, if it is connected to multi type outdoor unit, the maximum time for defrosting is 15 minutes.
(If the piping length used is longer than usual, frost will likely to form.)
Summary of Contents for RAC-50YH7
Page 22: ... 21 SHIFT VALUE ADJUSTMENT ...
Page 32: ... 31 Note 1 200mm or more servicing space is required above the outdoor unit ...
Page 35: ... 34 INDOOR UNIT OUTDOOR UNIT A A A A WIRING DIAGRAM MODEL RAS 80YH5A RAC 80YH5 ...
Page 36: ... 35 CIRCUIT DIAGRAM Remote Control ...
Page 37: ... 37 CIRCUIT DIAGRAM MODEL RAS 80YH5A ...
Page 38: ... 39 CIRCUIT DIAGRAM MODEL RAC 80YH5 ...
Page 40: ... 42 MODEL RAC 80YH5 MAIN P W B ...
Page 41: ... 43 MAIN P W B NF P W B CAPA P W B ...
Page 46: ... 51 ...
Page 49: ... 57 ...
Page 83: ... 92 SELF DIAGNOSIS LIGHTING MODE DD0002204A ...
Page 85: ... 94 2 Outdoor unit does not operate but receives remote infrared signal ...
Page 88: ... 97 CHECKING THE REMOTE CONTROLLER ...
Page 93: ... 102 16 ...
Page 103: ...PM NO 0413E Printed in Malaysia RAS 80YH5A RAC 80YH5 ...