10. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations]
・
Erroneous connection in the indoor-outdoor connection line (F cable)
・
Wire break or poor insertion of the indoor-outdoor connection line (F cable)
・
Electrical parts in the outdoor unit (communication circuit, power circuit error)
・
Communication error due to noise in other home electronics
※
This does not constitute a failure in the air-conditioner
[Cautions]
・
When lines A and B of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times", then, just in case, check if the F cable is not erroneously connected.
・
Detecting this failure mode turns off the power relay 3 minutes later and blocks the power
supply to the outdoor unit.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Yes
Yes
Yes
Yes
No
No
No
No
Correct the F cable connection.
Is the CN30 securely inserted into
the outdoor board?
Correct the connector.
Press the START/STOP button on the remote control
unit and start the product.
Are terminals A and B of the terminal board of the
electrical parts of the outdoor unit subjected to
220-230V AC?
※
Take measurements within 3 minutes after remote
control operation.
Check the electrical parts of the
outdoor unit.
Are terminals A and B of the terminal board of the electrical
parts of the indoor unit subjected to 220-230V AC?
※
Take measurements within 3 minutes after remote control
operation.
Double-check the F cable for erroneous connection,
wire break and poor insertion, and correct the
nonconforming parts.
Replace the "indoor control P.W.B".
1 . Timer lamp blinking: blinking 13 times
[Situation] The timer lamp blinks 13 times and the product will not run.
[Estimated failure location]
・
EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor control P.W.B".
1
・
・
Power realy open
Forget to connect CN30 of outdoor P.W.B
96
Summary of Contents for RAC-25FPA
Page 2: ... DANGER 2 ...
Page 32: ...WIRING DIAGRAM OF THE PRINTED WIRING BOARD Remote controller RAR 5E2 32 ...
Page 33: ...MODEL RAF 25RPA RAC 35RPA 33 ...
Page 34: ...MODEL RAC 25FPA RAC 35FPA 34 ...
Page 39: ...39 ...
Page 41: ...41 ...
Page 44: ...44 ...
Page 59: ...10 10 10 10 R921 R924 R642 R544 R542 R610 R922 DSW1 DSW1 R923 R541 R543 100 59 ...
Page 77: ... 3 3 1 77 ...
Page 82: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25 A RAC 35 A FP FP 82 ...
Page 98: ...98 36 ...
Page 99: ...99 ...
Page 100: ...100 59 ...
Page 101: ...101 ...
Page 113: ...38 39 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAF 25 35RPA 113 ...
Page 114: ...114 HWRAF 50NX2 A14 HBOARD AS ...
Page 117: ...RAF 25RPA RAC 25FPA RAF 35RPA RAC 35FPA HHAW NO 0069E 117 2 ...