5''
5''
5''
5''
5''
ON
OFF
OFF
OFF
ON
α
1. If a front panel open is detected when the
product has returned to its initial side in
response to a cleaning stop command, the
cleaner will stop but the cleaning lamp will
not blink.
2. This is not an error.
1. The product will be considered to have a startup error
when the logic of the limit switch has not changed for
more than 5 seconds after being started from the
initialization side.
2. The product will be considered to have an error when 3
startup errors are finalized.
2'46''+10''+α+2β
β
β
2'46''
5'' 5''
Limit
switch
Initialization
side
Operation lamp
Cleaning lamp
Power
Product command
Cleaning dr
iv
e
motor
Initialization
--> dust box
Dust box -->
initialization
Front panel
Open
Closed
Cleaning initiated
Cleaning initiated
Lit 1 second / dimmed 1 second
Lit 4 seconds / off 1 second
5. Automatic operation with the timer stopped
6. Servicing operation
Operation diagram for filter cleaning 4
(remarks)
1. Cleaning in general
(1) If, during cleaning, the remote control is used to start the
air-conditioner by cooling, heating, or other operation,
the cleaning will be stopped at that time. While the product
is being run, the cleaner will be returned to its initial position.
(2) The cumulative count of operating hours will be initialized
only when the cleaning has come to a normal end.
(1) If the air-conditioner auto-fresh holds while the product is
stopped, it will start to clean itself after that operation is over.
2. Automatic cleaning
3. Manual cleaning
(1) Pressing the "manual cleaning" key while the air-conditioner
is running will not work.
(2) This will not be activated while the sleep one-more timer is on.
(3) This will not be activated during initialization or automatic
cleaning.
(4) Pressing the MANUAL CLEANING key during manual
cleaning will abort the cleaning.
4. Forcible cleaning
(1) This will not be activated during mold monitoring, isolated
dirt monitoring, air-conditioner cleaning, nice temperature,
or auto-fresh.
(2) This will not be activated while the sleep one-more timer is on.
(3) This will not be activated for 20 minutes after preheating,
defrost, or preheating cancellation.
(1) The basic mode is the same as normal automatic cleaning.
(2) This will be performed for more than 20 cumulative hours
when stopped by the timer. In the meantime, if normal
automatic, manual, or forcible cleaning holds, the cumulative
20 hours will be initialized.
(1) This operation will run when cleaning is inhibited, regardless
of the time elapsed after the last cleaning.
(2) The product will run even when the front panel is open.
(3) All operations will be inhibited until the cleaner is returned
to its initial position.
(4) While the cleaner is in its servicing position, the air-conditioner
will run. It will not be forcibly returned to its initial position.
Operation diagram for filter cleaning (error detection 1)
Startup error
Front panel open
– 144 –