– 4 –
SPECIFICATIONS
MODEL
FAN MOTOR
FAN MOTOR CAPACITOR
FAN MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR MOTOR CAPACITOR
OVERLOAD PROTECTOR
OVERHEAT PROTECTOR
FUSE (MICRO COMPUTER CIRCUIT)
POWER RELAY
POWER SWITCH
TEMPORARY SWITCH
SERVICE SWITCH
TRANSFORMER
VARISTOR
NOISE SUPPRESSOR
THERMOSTAT
REMOTE CONTROL SWITCH (LIQUID CRYSTAL)
FUSE CAPACITY
RAS-18G5
30 W
NO
NO
–
NO
NO
NO
3.15A
G4A
YES
YES
YES
YES (SWITCHING
POWER SUPPLY)
450NR
NO
YES(IC)
YES
RAC-18G5
40 W
2.5
μ
F, 450V
YES (INTERNAL)
ASH210SV-C8LU
60
μ
F, 450VAC
YES (INTERNAL)
YES (INTERNAL)
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
20 A TIME DELAY FUSE
----------
1410g
ADDITIONAL REFRIGERANT R410A
AT 15g PER EVERY METER IF PIPE
LENGTH MORE THAN 8m.
UNIT
PIPES (MAX. 15m)
PIPES
(MIN.
1
5m)
REFRIGERANT CHARGING
VOLUME
(Refrigerant R410A)
Summary of Contents for RAC-18G5
Page 29: ... 27 MODEL RAC 18G5 ...
Page 33: ... 31 CIRCUIT DIAGRAM Remote Control ...
Page 34: ... 33 PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 18G5 ...
Page 35: ... 35 BLOCK DIAGRAM MODEL RAS 18G5 RAC 18G5 ...
Page 39: ... 43 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18G5 RAC 18G5 ...
Page 51: ... 55 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 18G5 ...
Page 53: ...PM NO 0485E Made in Malaysia RAS 18G5 RAC 18G5 ...