LD301 blinks 6 times.
The temperature at the
OH thermistor rises.
Is the thermistor circuit
normal?
Replace parts in the
thermistor circuit.
LD301 blinks 5 times.
Overload lower limit cut.
Replace the main
P
.W
.B.
Check to see if the refrigerating cycle is defective.
Check the indoor unit for clogged heat exchanger or filter
.
Check the outdoor unit for defective shielding.
LD301 blinks 4 times.
Failure of switching.
Is the 15V power supply
output normal?
(Power P
.W
.B. display)
Is the intelligent power
module (IPM) normal?
(Inverter section)
The intelligent power module
may be defective.
Replace the main
P
.W
.B.
See “System Power
Module Diagnosis”.
With CN3 and CN4
disconnected, is the 15V
output between
“15V” and
”15-0V” on the power
P
.W
.B.?
Replace the power P
.W
.B.
LD301 blinks 3 times.
Abnormal low speed.
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Yes
No
No
No
No
No
No
No
※
※
※
※