- 35 -
Operation lamp
Two-way air
exchange lamp
Indoor fan
Horizontal air
deflector
Operation status
of main unit
Exhaust operation
Fresh air in operation
Dirt sensor
Dirt judgment
ON
Dirt criteria
Fan Lo
Fan position
Forced for 20mins
Forced for 20mins
20min.
5sec.
Operation mode set by remote control
Main unit operatesMain unit operates
Main unit operates
If outdoor temperature
≦
room temperature
+10˚C after the exhaust operation is
finished, fresh air in operation starts
.
Dirt judgment cancelled
Dirt judgment cancelled
Automatic Two Way Air Exchange Mode
Fresh Air In During Sleep Mode
Notes:
(1) Two way air exchange operation is performed automatically when dirty air is detected by setting
“Automatic Two Way Air Exchange”.
(2) Exhaust operation is performed until the air becomes clean. Forced operation is performed for 20
minutes. The maximum exhaust period is 5 hours.
(3) If outdoor temperature
≦
room tempe10
˚
C at the time the exhaust operation is finished
,
fresh air in operation is performed for 20 minutes.
(4) If Air Monitor operation is performed while the air conditioner is stopped, the air conditioner runs
at the fan operation mode while exhaust and fresh air in operations are performed
.
(5) If Air Monitor operation is performed while the air conditioner is in operation, the air conditioner
runs according to the operation mode selected by the remote control while exhaust and fresh air
in operations are performed. At this time, the operation lamp is lit
.
(6) “Automatic Two Way Air Exchange” is inhibited for 8 hours after sleep operation reservation is
made.
(7) “Automatic Two Way Air Exchange” setting will be cancelled automatically after 14 days have
elapsed since the setting is made.
Notes:
(1) When the sleep operation (including 1 more timer operation) is performed while the “Fresh Air In
During Sleep Mode” is set, the fresh air in operation is performed. (Fresh air in during sleep
mode is inhibited while operating exclusive two way air exchange and heating.)
(2) Forced fresh air in operation is performed for 30 minutes after sleep operation reservation is
made.
(3) Judgment of the following fresh air in inhibiting conditions is made every 30 minutes after sleep
operation reservation is made.
(a) Outdoor temperature
≧
Room tempe1˚C
.
(b) Room temperature
≦
Set temperature -2˚C
(4) Two way air exchange fan operates at the sleep tap
.
Remote control
Timer lamp
Operation lamp
Two way air
exchange lamp
Indoor fan
Horizontal air deflector
Main unit operation
Fresh air in operation
Fresh air in judgment
Cooling sleep operation
Cooling sleep operation
Cooling sleep operation
Cooling position
Forced for 30 mins
Shut
Shut
1 more monitoring
Forced for 1hr
Forced for 1hr
1 more inhibited
1-hour cooling sleep reservation
5min. (fresh air in judging time)
30min.
30min.
30min.
30min.
30min.
30min.
30min.
30min.
30min.
Sleep position
Cooling 1 more operation
Operation mode set by remote control