– 35 –
EN
GLIS
H
W
ARNING
W
ARNING
REGULAR INSPECTION
1
2
3
Chec
k to see if the unit’
s ear
th line has been connected
correctl
y.
If the ear
th line is disconnected or f
aulty
, unit f
ailure or electr
ic
shoc
k hazard ma
y result.
Chec
k to see if the mounting frame has rusted e
xcessivel
y
or if the outdoor unit has tilted or become unstab
le
.
It could collapse or fall, causing injur
y.
PLEASE CHECK
THE FOLLO
WING POINTS EVER
Y EITHER HALF
YEARL
Y OR
YEARL
Y
. CONT
ACT
Y
OUR SALES
A
G
ENT SHOULD
Y
OU NEED ANY HEL
P.
Chec
k to see if the po
wer plug is securely
inser
ted into the
wall socket.
If the po
wer
plug is not inser
ted into the wall
soc
ket securely
, it
will become hot and an electric
shoc
k or fire ma
y occured.
If dust
or dir
t is f
ound on the po
wer
plug, clean the plug and inser
t it into
the wall soc
ket.
W
ARNING
AFTER SALES SERVICE AND WARRANTY
CONDITION
CHECK
THE FOLLO
WING POINTS
•
Do the batter
ies need replacement?
•
Is the polarity of the inser
ted batter
ies correct?
•
Is the air filter bloc
ked with dust?
•
Is the set temper
ature suitable?
•
H
a
ve hor
iz
ontal air deflectors been adjusted to their correct positions
according to the oper
ation mode selected?
•
Are the air inlets or air outlets of indoor and outdoor units b
loc
ked?
•
Is the f
an speed
“LO
W”
or
“SILENT”?
•
Is the fuse all right?
•
Is the voltage e
xtremely high or low?
•
Is the circuit breaker
“ON”?
•
Is the power plug inser
ted?
•
Do y
ou ha
ve
an
y po
w
er cut?
When it does not operate
.
When it does not cool w
ell.
When it does not heat w
ell.
If the remote controller is not
transmitting a signal.
(Remote controller displa
y is
dim or blank.)
WHEN ASKING FOR SER
VICE,
CHECK
THE FOLLO
WING POINTS.
■
The f
ollo
wing phenomena do not indicate unit f
ailure
.
<Operation start>
The unit is preparing to blow warm air. Please wait.
<In operation>
The outdoor unit is defrosting. Please wait.
Hissing or fizzy sounds
Refrigerant flow noise in the pipe or valve sound generated when flow rate is
adjusted.
Squeaking
noise
Noise generated when the unit expands or contracts due to temperature changes.
Rustling noise
Noise generated with the indoor unit fan’s rpm changing such as operation start
times.
Clicking
noise
Noise of the motorized valve when the unit is switched on.
During heating, the operation indicator
blinks and air blow stops
– 36 –
Perking noise
Noise of the ventilation fan sucking in air present in the drain hose and blowing out
dehumidifying water that had accumulated in the condensed water collector. For
details, consult your sales agent.
Changing operation noise
Operation noise changes due to power variations according to room temperature
changes.
Mist
emission
Mist is generated as the air within the room is suddenly cooled by conditioned air.
Steam emitted from the outdoor unit
Water generated during defrosting operation evaporates and steam is emitted.
Odors
Caused as the smells and particles of smoke, food, cosmetics, etc. present in room
air become attached the unit and blown off into the room again.
Defrosting is underway (as the heating operation is stopped, the microcomputer
checks frost accumulated in the indoor unit and instructs the unit to perform
automatic defrosting if necessary).
Shows preheating or defrosting operation is underway.
As the protective circuit or preheat sensor operates when unit operation is stopped
during preheating and then restarted, or when operation mode is switched from
cooling to heating, the lamp continues to blink.
Actual room temperature may deviate slightly from the remote controller’s temperature
setting depending on the number of people in the room, indoor or outdoor conditions
when the air conditioner is used for more than one room at the same time.
•
If the unit still f
ails to oper
ate
nor
mally after perf
or
ming the
abo
ve
inspections, tur
n the circuit
break
er off and contact y
our sales
agent immediately
.
•
Please contact y
our sales agent immediately if the air conditioner still f
ails to oper
ate nor
mally after the abo
ve
inspections
.
Inf
or
m y
our agent of the model of y
our unit, production number
, date of installation.
Please also inf
or
m him regarding
the f
ault.
( )
Contact y
our sales a
g
ent immediatel
y if the f
ollo
wing
phenomena should occur:
•
The circuit break
er s
witches off or the fuse b
lo
w
s
frequently
.
•
The s
witch oper
ation is not stab
le
.
•
F
oreign matter or w
ater accidentally enters the unit interior.
•
The po
wer
cord gets e
xcessiv
ely hot or its insulation is tor
n or str
ipped.
•
TIMER lamp or FIL
TER lamp on the indoor unit indicators b
links
.
As the nature of the f
ailure can be identified b
y
the blinking
cycle
, chec
k
the b
linking cycle bef
ore tur
ning off the circuit breaker
.
Notes
•
In quiet operation or stopping the r
unning, the f
ollowing
phenomena ma
y occasionally
occur
, b
ut the
y are not abnor
mal f
or the operation.
(1)
Slight flowing noise of refrigerant in the refrigerating cycle.
(2)
Slight rubbing noise from the fan casing which is cooled and then gradually
warmed as operation stops.
•
The odor will possib
ly be emitted from the room air conditioner because the v
a
ri
ous
odor
, emitted b
y
smok
e, f
oodstuffs
, cosmetics and so on, stic
ks to it.
So please clean
the air filter and the
e
v
apor
ator regularly to reduce the odor
.
The outdoor unit contin
ues to oper
ate
e
ven if oper
ation is stopped.
The OPERA
TION lamp is b
linking.
Does not reach the temper
ature
setting.
Please note:
On s
witching on the equipment, par
ticular
ly when the room light is dimmed, a slight brightness
fluctuation ma
y
occur
. This is of no consequence
.
The conditions of the local
P
o
w
er Supply Companies are to be obser
ved.
- 21 -