LD301 blinks 12 times.
Fan lock error
.
Is CN24 connected?
Is the propeller fan
locked?
Have the 1A
fuse and
R107 blown?
Is +15V being generated?
Check voltage both between
CN18 4 and 5 on the main
P
.W
.B., and between
+15V
and
15-0V
(silk-screened) on
the power P
.W
.B.
If no output voltage is present
on the power P
.W
.B. side,
replace the power P
.W
.B.
Is the fan operating?
(An error occurs after the
fan operates for 2 minutes.)
Is the voltage between 4
and 6 at CN24 normal
?
(Normally
, the voltage is
above approx. DC1.7V
.)
Connect the connector
.
Remove any
obstructions.
Replace the fan motor
and main
P
.W
.B.
Is the voltage between 4 and
7 at CN24 normal
?
Check to see if the voltage is
within 2.5V
±
0.5V using a
tester
.
(In ef
fect, the output voltage
is alternately switched
between 5V and 0V
.)
Replace the main
P.
W
.B
.
Replace the fan motor
.
Ye
s
No
No
No
Ye
s
No
No
No
No
No
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
※
- 92 -