--- 16 ---
Remove the adhesive
fragments and apply oil to
the nail feeder, ribbon
spring, guide rail and the
nail rail.
<
Driving section: nose,
pushing lever>
Nail inlet groove of the nose
is abnormal (deformed,
burrs or damaged).
Adhesive fragments are in
the nail inlet groove.
Problem
Possible cause
( : Most-common cause)
Inspection method
Remedy
9. TROUBLESHOOTING GUIDE
9-1. Troubleshooting and Correction
1) Nails cannot
be driven.
<Nails>
Magazine is not loaded with
specified genuine nails.
Magazine is loaded with
abnormal nails (bent nails,
large or small round-head
nails, abnormal collation,
etc.).
Nails or collating band
clogs.
Collating band is deformed
or torn.
<
Magazine section>
Magazine is abnormal
(deformed or damaged).
Nail feeder is abnormal
(deformed or damaged).
Ribbon spring is abnormal
(deformed or damaged).
Guide plate is abnormal
(deformed, burrs, damaged
or fatigued).
Nail rail is abnormal
(deformed, burrs, damaged
or fatigued).
Adhesive fragments are on
the guide plate and the nail
rail or they need oil.
Check if the magazine is
normally loaded with
specified nails.
Check if the nail feeder
operates smoothly in the
magazine.
Check if nails (one strip)
move smoothly in the
magazine.
Use specified nails.
Remove the abnormal nails
and load the magazine with
normal nails.
Check if nails (one strip) are
fed smoothly into the nail
injection port of the nose.
Pushing lever
Check the operation of the
pushing lever.
Repair or replace the
defective parts.
Repair or replace the
defective part.
Remove the adhesive
fragments.
Correct or replace the parts.