1. GETTING STARTED
1-2
1.2 Installation Environment
1.2.1 Environment
CAUTION
If you keep at high temperature this equipment, do not touch bare hands.
Otherwise you may result burns.
When this equipment is used, it must be used in the following environment.
(*1)
Item
Requirement
Ambient temperature
Operation: 5 to 40°C
Storage: -10 to 60°C
Temperature gradient
±10 K/h or less
Humidity
20 to 80%RH (non-condensing)
Humidity gradient
± 10% RH/h or less
Dust (*2)
No heavy dust
(0.3 mg/m
3
or less (JEITA IT-1004A class B))
Corrosive gas
None
JEITA IT-1004A class A (Temperature 25
℃
,
Humidity 50% RH)
Vibration resistance
4.9 m/s
2
(10 Hz, 5 s)
Shock resistance
Operation: 19.6 m/s
2
(while not powered on: 98 m/s
2
)
Power voltage
100 to 240 VAC (*3)
Power frequency
50/60 Hz ± 3 Hz
Power supply noise
2.0 kV (fast transient / burst wave)
Electrostatic noise contact
discharge
4 kV (Air: 8 kV) (*4)
Insulation resistance
500 VDC, 5 M
Ω
Dielectric strength
1.5 kVAC, one minute
Transient power fault
10 ms or less
Altitude
1000 m or less.
(*1)
Environmental conditions that must be satisfied are the same for HF-BX1000 and
HF-BX1200.
(*2) This equipment cannot be used in the environment where conductive dust or the
like is floating.
(*3) If a square wave uninterruptible power supply (UPS) is connected to the
equipment, the equipment may fail. Do not use this type of UPS.
(*4) Be cautious when you use the equipment in the environment subject to noise such
as electrostatic noise. Depending on the severity of the noise, failures such as a
disruption on the LAN may occur. When a user builds a system, make sure that
the system can recover (retry) automatically.
< NOTE >
• For information about the precautions for the environment, see
“PRECAUTIONS 1. PRECAUTIONS ABOUT THE EQUIPMENT
(5) INSTALLATION ENVIRONMENT”.
Summary of Contents for HF-BX1000
Page 1: ...BX 62 0001 01 ...
Page 2: ...BX 62 0001 01 ...
Page 61: ...This Page Intentionally Left Blank ...