6. TROUBLESHOOTING
6-18
Table 6-2 lists event log entries unique to the equipment. No.1 through 12 and No.14 through
21 are collected in the system log, and Nos.13 is collected in the application log.
Table 6-2 Event Log Entries Unique to the Equipment (1/2)
No. Event ID
Source
Type
Category
Description
Action
1
259
HFBRAS_SYS Warning HFBRAS The temperature exceeded
prescribed value.
Read the description of
abnormal temperature in “6.2.2
(1)” and take action
accordingly.
2
260
HFBRAS_SYS Information HFBRAS Remote shutdown request
occurred.
No handling.
3
263
HFBRAS_SYS Information HFBRAS Temperature returned to
prescribed value.
No handling
4
265
HFBRAS_SYS Warning HFBRAS Immediately back up your
data and replace drive.
A failure may be imminent
on the drive of the drive
bay%1 (%2).
We recommend you back up
the data and replace the drive.
5
266
HFBRAS_SYS
Error
HFBRAS Revolutions of cpu fan
deteriorated remarkably.
Read the description of fan
failure in “6.2.2 (1)” and take
action accordingly.
6
267
HFBRAS_SYS Information HFBRAS Revolutions of cpu fan
returned to normal value.
No handling.
7
268
HFBRAS_SYS
Error
HFBRAS The computer was shut
down because temperature
became dangerous.
Read the description of
abnormal temperature in “6.2.2
(1)” and take action
accordingly.
8
270
HFBRAS_SYS Information HFBRAS Used hours on the drive of
the drive bay%1 exceeded
prescribed value.
We recommend you back up
the data and replace the drive.
9
274
HFBRAS_SYS
Error
HFBRAS Revolutions of case fan
deteriorated remarkably.
Read the description of fan
failure in “6.2.2 (1)” and take
action accordingly.
10
275
HFBRAS_SYS Information HFBRAS Revolutions of case fan
returned to normal value.
No handling.
11
524
HFBRAS_SYS Information HFBRAS In the current settings,
memory dump file won’t
be saved.
Change the setting according to
“7.3.2”.
12
539
HFBRAS_SYS
Error
HFBRAS The “%1” was finished.
Hardware monitoring of the
RAS software has been
terminated. If restarting the
equipment does not resolve the
error, contact the system
administrator or maintenance
personnel.
13
769
HFBRAS_APP
Error
HFBRAS An error occurred in %1.
errorcode = %2.
Hardware monitoring of the
RAS software has been
terminated. If restarting the
equipment does not resolve the
error, contact the system
administrator or maintenance
personnel.