4. CHECKING THE HARDWARE STATUS
4-30
Table 4-11 shows a list of the objects related to the RAS function settings and a
description of those objects. The object ID of each object is obtained by either replacing
the following “x” with the object in the following table or replacing the following “y”
with the object number in the table.
Object ID: .iso.org.dod.internet.private.enterprises.Hitachi.systemExMib.
hfwExMib.hfwRasSetting.x (x is an object in the table below)
or
.1.3.6.1.4.1.116.5.45.2.y (y is an object number in the table below)
Table 4-11 Objects Related to the RAS Function Settings
No.
Object
Object
number
Description
Description of the
values
1
hfwFanAutoShutdown
1
Automatic shutdown when a fan failure occurred
1: Enabled
2: Disabled
2
hfwTempAutoShutdown
2
Automatic shutdown when the temperature is
abnormal
1: Enabled
2: Disabled
3
hfwSmartEnableSetting
4
Drive Failure Prediction (SMART monitoring)
1: Enabled
2: Disabled
Table 4-12 shows a list of the objects related to operational modes and a description of
those objects. The object ID of each object is obtained by either replacing the following
“x” with the object in the following table or replacing the following “y” with the object
number in the table.
Object ID: .iso.org.dod.internet.private.enterprises.Hitachi.systemExMib.
hfwExMib.hfwRasInfo.x (x is an object in the table below)
or
.1.3.6.1.4.1.116.5.45.3.y (y is an object number in the table below)
Table 4-12 Objects Related to Operational Modes
No.
Object
Object
number
Description
Description of the values
1
hfwRasMode
1
Operation mode
1: Normal mode
2: Simulation mode