7. FEATURES RELATED TO MAINTENANCE AND FAILURE ANALYSIS
7-6
7.2.3 Logging interval setup command
<Name>
tmplogset - Setting up the logging interval
<Syntax>
tmplogset
<Function>
This command configures the interval for logging the trend of the temperature inside the chassis.
The following shows how to use the command.
1. Start Command Prompt.
You need to have administrator privileges to run this command. Log on to the computer as an
administrator account and start Command Prompt.
If User Account Control (UAC) is enabled, start the command prompt as an administrator
according to “APPENDIX A RUNNING COMMAND PROMPT AS AN
ADMINISTRATOR”.
2. At the command prompt, run the tmplogset command. The following initial screen is displayed
along with the current setting.
3. If you type 2 in the initial screen, the tmplogset command exits without changing the setting. If
you type 1 and then press
Enter
, the following message is displayed.
Please select new time of the cycle.
When the return is input, it becomes like a present setting.
1. 10 minutes
2. 30 minutes
3. 60 minutes
:
_
>tmplogset
Logging time of the cycle
:
60 minutes
1. Change at logging cycle [10,30,60 minutes]
2. Exit
:
_