3. SETTING UP THE RAS FEATURE
3-12
z
Advanced
button
Click
Advanced
to display the following window.
Other than D Model
D Model
Figure 3-9 Advanced Settings for the Popup Notification Setting
[Events]
• Fan failure
• Abnormally high temp.
• Drive failure prediction (SMART)
• Drive usage excess (When the drive power-on (=used) hours exceeds the threshold)
• RAID error is detected (D Model only)
You can disable or enable popup notification for each of the items above.
z
Check box for each item
• Selected: The popup notification is enabled. (factory-shipped default setting)
• Cleared: The popup notification is disabled.
If you want to change the current setting, click the check box.
[Message editing]
You can edit popup notification messages. And you can check the messages after you
edit them. For information about how to edit and check the messages, see “3.1.4
Editing popup notification messages”.
If you changed the advanced setting and want to make the change effective, click
OK
.
If you do not want the change, click
Cancel
. Then the window is closed and the
change is inapplicable.
(7) Making the change you made in (1) through (6) effective or discard the changes
If you changed the settings in (1) through (6) and want to make the change effective, in
the
RAS Setup
window, click
OK
. If you do not want to change the setting, click
Cancel
. Then the
RAS Setup
window is closed and the changes are discarded.