Troubleshooting 52
5.
Remove the USB key.
6.
Reboot the system and press
F10
(IP Recovery) to verify IP Recovery launches properly.
Solution 2
Cause
The iLO is running in FIPS mode.
Action
1.
Enter the iLO configuration screen and turn off FIPS mode.
2.
Boot the server into F10 mode.
3.
After making all changes, enable FIPS mode.
Intelligent Provisioning PXE flashing doesn't re-image Always On Intelligent
Provisioning
Symptom
Intelligent Provisioning PXE flashing doesn't re-image Always On Intelligent Provisioning
Note: User should follow the above said command lines only for the reference and are not recommended
to copy the same
Action
Update the Kernel command line with the word "Install". For example:
linuxefi /IP3.30/vmlinuz media=net splash quiet iso1=http://
192.168.100.101/iso/IP330.2019_0103.230.iso iso1mnt=/mnt/bootdevice
nicmac=5c:b9:01:c5:43:d0 install
echo 'Loading initial Ramdisk...'
initrdefi /IP3.30/initrd.img
NOTE:
Modify the example to fit your system's details.
OS Host name field missing
Symptom
The OS Host name field on the
Intelligent Provisioning Assisted Install > OS selection
page is
missing.