28
2. Equipment connection and network setting
2.5.5 Alert Settings (Continued)
Setting Item
Description
Alarm Time
Configures the time to alert.
(Only Lamp Time Alarm and Filter Time Alarm.)
SNMP Trap
Click the
[Enable]
check box to enable SNMP Trap alerts.
Send Mail
Click the
[Enable]
check box to enable e-mail alerts.
(Except Cold Start and Authentication Failure.)
Mail Subject
Configures the subject line of the e-mail to be sent.
The length of the subject line can be up to 255 alphanumeric
characters.
(Except Cold Start and Authentication Failure.)
Mail Text
Configures the text of the e-mail to be sent.
The length of the text can be up to 1024 alphanumeric
characters.
(Except Cold Start and Authentication Failure.)
2.5 Configuring and controlling the projector via a web browser (Continued)
The Alert Items are shown below.
• The trigger of Filter Error e-mail is depending on the Filter Message
settings in the SERVICE menu which defines the period of Filter Message on
the projector screen. The e-mail will be sent when the filter timer exceeds 50,
100, 200 or 300 hours based on the configuration. No notification e-mail will
be sent if the configuration is TURN OFF. (
OPTION Menu
of the
User’s Manual -
Operating Guide
)
• Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of
the lamp timer. When the lamp hour exceeds this threshold that is configured
through the Web page, the e-mail will be sent out.
• Filter Time Alarm is defined as a threshold for e-mail notification (reminder)
of the filter timer. When the filter hour exceeds this threshold, the e-mail will be
sent out.
NOTE
Click the
[Apply]
button to save the settings.