4-9 AIR-FLOW-SENS adjustment
When the PWB assembly MAIN is replaced, perform this adjustment after completing reassembling the pro-
jector.
1. Set the item “WHISPER” to “NORMAL”, then warm up for 5 minutes or more.
2. Open HIDDEN SERVICE MENU with the following procedure and choose ”AIR-FLOW-SENS” by using
[▼] button.
How to open HIDDEN SERVICE menu
By the control panel
By the remote control transmitter
1. Display the Advance menu by
the “MENU” button. (If EASY
MENU appears, choose “Go to
Advance menu” to display
ADVANCE MENU.)
2. Select the “OPTION” on the
menu.
3. Continue press the button [ ]
fi rst, then press the button [ ]
together with “INPUT” and hold
for 3 seconds.
1. Display the Advance menu by
the “MENU” button. (If EASY
MENU appears, choose “Go to
Advance menu” to display
ADVANCE MENU.)
2. Select the “OPTION” on the menu.
3. Press the “MAGNIFY OFF”
button.
Next hold the “MAGNIFY OFF”
button for 3 seconds.
3. Pressing the [►] button displays the adjustment window. Use the [▲] button to select EXECUTE. The
automatic adjustment program runs.
4. After the message of “END” is displayed in the window, read the given offset value and make sure that it is
in the range; 120 offset: 170.
5. Next, select <<NORMAL>> using [▼] button. Pressing [◄] / [►] button changes to <<WHISPER>>. Wait
for 30 seconds or more before following operations.
6. Perform the same operations as the steps 2 and 3 above.
7. After the message of “END” is displayed, read the given offset value and make sure that it is in the range;
90 Offset: 150
8. If both or either of offset values are out of the specified ranges, make sure the below conditions. Then
retry the same adjustments.
1) The air filter is not choke up with dust.
2) No lose connection of connector E301 and E302.
9. If the adjustments failed after treatment, replace either of next parts.
1) PWB assembly MAIN
2) DC FAN (panel)
3) Thermal sensor (inside)
HIDDEN SERVICE
FILTER TIME ON
MUTE COLOR BLACK
AIR-FLOW-SENS
SOFT RESET
EXECUTE
CANCEL
AIR-FLOW-SENS
offset:127
<<NORMAL>>
EXECUTE
CANCEL
AIR-FLOW-SENS
offset:139
END
<<NORMAL>>
Summary of Contents for CP-S335W
Page 46: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...
Page 59: ...58 CP S335 C9SM CP X340 PJ552 C9X CP X345 PJ562 C9XM MEMO ...
Page 61: ......
Page 62: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly CONTROL C9SM C9X C9XM ...
Page 63: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 1 C9SM C9X C9XM ...
Page 64: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 2 C9SM C9X C9XM ...
Page 65: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 3 C9SM C9X C9XM ...
Page 66: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 4 C9SM C9X C9XM ...
Page 67: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 5 C9SM C9X C9XM ...
Page 71: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 9 C9SM C9X C9XM ...
Page 72: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 10 C9SM C9X C9XM ...
Page 73: ...A B C D E F G 5 4 3 2 1 6 6 5 4 3 2 1 PWB assembly MAIN 11 C9SM C9X C9XM ...