PERIODIC SERVICE 11-17
4. Adding the LLC
1) Add only water if the mixture reduces in
amount by evaporation.
2) If there is a mixture leak, add the LLC of the
same manufacturer and type in the same
mixture percentage.
* Never add any long-life coolant of different
manufacturer.(Different brands may have
different additive components, and the
engine may fail to perform as specified.)
5. When the LLC is mixed, do not employ any
radiator cleaning agent. The LLC contains
anticorrosive agent. If mixed with the cleaning
agent, sludge may build up, adversely
affecting the engine parts.
6. The v
ehicle’s original long-life coolant has a
service life of 2 years. Be sure to change the
coolant every 2 years.
NOTE:
The above data represents industry standards
that necessitate a minimum glycol content in
the concentrated antifreeze.
When the coolant level drops due to
evaporation, add water only to keep the
antifreeze mixing ratio less than 50%. In case
of leakage, add antifreeze and water in the
specified mixing ratio before filling into the
radiator.
■
Replacing Radiator Hose (Water pipes)
Replace the hoses and clamps.
(See “Checking Radiator Hose and Clamp” in
“EVERY 200 HOURS” in “PERIODIC SERVICE”
section.)
■
Replacing Fuel Hose
Consult your local HISUN Dealer for this service.
■
Replacing Brake Master Cylinder (Inner
parts)
Consult your local dealer for this service.
■
Replacing Front Brake Seal
Consult your local dealer for this service.
■
Replacing Rear Brake Cylinder Seal
Consult your local dealer for this service.
■
Replacing Intake Air Line
Consult your local dealer for this service.
EVERY 4 YEARS
■
Replacing Brake Hose
Consult your local Dealer for this service.
■
Replacing Slow-Blow Fuses
The slow-blow fuses are intended to protect the
electrical cabling. If any of them have blown out, be
sure to pinpoint the cause.
◆
Replacing procedure
1) Disconnect the negative cable of the battery.
2) Open the slow-blow fuse box cover.
3) Pull out the slow-blow fuse.
4) Insert a new slow-blow fuse into the slow-blow
fuse box.
5) Close the slow-blow fuse box cover.
6) Connect the negative battery cable.
Summary of Contents for VECTOR 500
Page 12: ...SAFE OPERATION 1 5 11 Warning and caution labels...
Page 13: ...SAFE OPERATION 1 6...
Page 14: ...SAFE OPERATION 1 7...
Page 19: ...INSTRUMENT PANEL AND CONTROLS 5 1 INSTRUMENT PANELAND CONTROLS LOCATION OF PARTS...
Page 20: ...INSTRUMENT PANEL AND CONTROLS 5 2 ILLUSTRATED CONTENTS...
Page 21: ...INSTRUMENT PANEL AND CONTROLS 5 3...
Page 31: ...OPERATING THE VEHICLE 8 6 Hourmeter The speedometer indicates the traveling speed Speedometer...
Page 67: ...TM HISUN MOTORS 310 East University Dr McKinney Texas 75069 PH 972 446 0760 hisunmotors com...