Page 4 of 36
三、
FEATURES:
1. DC inverter and Energy-saving environmental protection;
2. Large heating capacity
;
3. Auxiliary heating design
;
4. Voice function;
5. Ionic air purification technology
;
6. Design of the wind on three sides
7. Large-size LED screen, with adjustable brightness feature;
8. Color trims, with the color change control
;
9. Touch keys, Polyphonic Ringtones turning on or off;
10. Sliding Mechanism Design; The upper panel with a motion mechanism, slide up
when heating, And the wind out of the central. However, the upper panel is still and
the wind out of the top when cooling. The wind out of the central when heating and
out of the top when cooling, which is more conducive to hot and cold air convection
indoor, and improve the efficiency of heat exchange.
3.1
Main functions
3.1.1
Complete functions
Cooling, heating, dehumidification, automatic, blasting and so on. Various models
are complete and can realize various functions.
3.1.2
Touch-screen
Through the touch-screen, can intelligently adjust various refrigeration, heating and
other functions, as well as wind speed, temperature and other parameters.
3.1.3
Ultra-Low Noise
Indoor use the three sides inlet means of both sides and the bottom,
Optimization duct design, Quiet running noise.
3.1.4
Ion Purification
Efficient cold plasma can effectively remove the harmful substances indoors.
3.1.5
Sliding panel Features
When heating, the upper panel slides into the top and the middle baffle open.
When cooling or off, the upper panel slides into the bottom and Covers the middle
baffle, for beautiful and generous.
3.2
Technical Features
3.2.1
Characteristics of the circuits:
①
Compressor Drivers use single-supply and low-cost IPM module program, and
improved system integration and reliability.
②
Compressor drive circuits use no
optocoupler and non-isolated driver program.
③
System control and module driver are separated control, use asynchronous
communication mode for communication.
Summary of Contents for 88FZBpC
Page 1: ...KFR 72LW 88FZBpC Maintenance manual Hisense Kelon Air Conditionning Co Ltd...
Page 4: ...Page 3 of 36 OUTLINES 2 1 INDOOR 2 2 OUTDOOR 2 3 REMOTE...
Page 14: ...Page 13 of 36 ELECTRICAL DATA 7 1 Electric Wiring Diagrams 7 1 1 Indoor 7...
Page 15: ...Page 14 of 36 7 1 2 Outdoor...
Page 16: ...Page 15 of 36 7 2 Refrigerant Flow Diagram 7 3 System pressure diagram...
Page 17: ...Page 16 of 36...
Page 18: ...Page 17 of 36 7 4 Air conditioning Appearance Dimension Drawing 1 Indoor...
Page 19: ...Page 18 of 36 2 Outdoor...