Hisense 88FZBpC Maintenance Manual Download Page 30

 

Page 29 of 37 

17 88.612 

73 

0.3564 

18 85.042 

76 

0.3711 

19 81.637 

79 

0.3857 

20 78.388 

82 

0.4004 

21 75.287 

85 

0.415 

22 72.326 

88 

0.4297 

23 69.498 

91 

0.4443 

24 66.795 

95 

0.4639 

25 64.21 

98 

0.4785 

26 61.739 

102 

0.498 

27 59.373 

105 

0.5127 

28 57.11 

109 

0.5322 

29 54.942 

113 

0.5518 

30 52.866 

117 

0.5713 

31 50.876 

121 

0.5908 

32 48.939 

125 

0.6104 

33 47.14 

129 

0.6299 

34 45.386 

133 

0.6494 

35 43.703 

138 

0.6738 

36 42.087 

142 

0.6934 

37 40.536 

147 

0.7178 

38 39.047 

152 

0.7422 

39 37.616 

157 

0.7666 

40 36.24 

162 

0.791 

41 34.919 

167 

0.8154 

42 33.648 

172 

0.8398 

43 32.426 

178 

0.8691 

44 31.25 

183 

0.8936 

45 30.119 

189 

0.9229 

46 29.03 

194 

0.9473 

47 27.982 

200 

0.9766 

48 26.973 

206 

1.0059 

49 26.001 

212 

1.0352 

50 25.065 

219 

1.0693 

51 24.163 

225 

1.0986 

52 23.295 

231 

1.1279 

53 22.457 

238 

1.1621 

54 21.65 

245 

1.1963 

55 20.873 

252 

1.2305 

56 20.123 

259 

1.2646 

57 19.399 

266 

1.2988 

58 18.702 

273 

1.333 

59 18.029 

280 

1.3672 

60 17.38 

288 

1.4063 

Summary of Contents for 88FZBpC

Page 1: ...KFR 72LW 88FZBpC Maintenance manual Hisense Kelon Air Conditionning Co Ltd...

Page 2: ...ment 7 5 2 Cooling run mode 19 5 3 Heating run mode 10 5 4 Dehumidifying mode 11 5 5 Air blowing mode 11 5 6 Dual mode 12 ELECTRICAL DATA 13 6 1 Electric Wiring Diagrams 13 6 2 Refrigerant Flow Diagra...

Page 3: ...Page 2 of 36 MODEL AND BRAND 1 1 Model KFR 60LW 88FZBpC 1 2 Marketing Trademark Hisense Trademarks 1 3 Short Selling Frequency And Energy Saving...

Page 4: ...Page 3 of 36 OUTLINES 2 1 INDOOR 2 2 OUTDOOR 2 3 REMOTE...

Page 5: ...Various models are complete and can realize various functions 3 1 2 Touch screen Through the touch screen can intelligently adjust various refrigeration heating and other functions as well as wind sp...

Page 6: ...with the large area of condenser and evaporator So air conditioner could run stable and reliable and energy efficient 3 2 3 Structural features Indoor structural elements is a new design Panels The u...

Page 7: ...ing frequency range Minimum Max Hz 25 105 Rated Heating Capacity Rated input power of low temperature heating kW 6 5 2 80 Rated Input Current Maximum Input Current A 11 4 20 0 Maximum Input Power kW 4...

Page 8: ...lay CPU receiving the signal from the indoor control board 6 1 4 Key Operation 6 1 4 1 Switch Key ON or OFF 6 1 4 2 Mode Key Switching mode cycle 6 1 4 3 Speed Key Switching wind speed loop 6 1 4 4 Te...

Page 9: ...uring the time of sleep mode the set temperature will change automatically The air conditioner will turn off and cancel the sleep function after the sleep function works for 8 hours 6 1 8 High efficie...

Page 10: ...thods see the corresponding mode 6 1 15 4 If shut down when the left throttle or intermediate damper in positioning uninterruptible power shutdown the leaves should be restored to the shutdown positio...

Page 11: ...en fixed and swept according to the remote The left right throttle is targeted to the minimum position in cold air prevention mode 6 3 1 2 The blades of the top throttle control The top throttle is fi...

Page 12: ...ange from cooling to heating it needs an interval of 50 seconds for the 4 way valve to change over from being interrupted to being electrified 6 3 6 Auxiliary Heating The unit automatically starts Aux...

Page 13: ...age 12 of 36 6 6 Dual mode 6 6 1 Comfort mode is separated cooling comfort mode and heating comfort mode 6 6 2 Energy saving mode is separated cooling energy saving mode and heating energy saving mode...

Page 14: ...Page 13 of 36 ELECTRICAL DATA 7 1 Electric Wiring Diagrams 7 1 1 Indoor 7...

Page 15: ...Page 14 of 36 7 1 2 Outdoor...

Page 16: ...Page 15 of 36 7 2 Refrigerant Flow Diagram 7 3 System pressure diagram...

Page 17: ...Page 16 of 36...

Page 18: ...Page 17 of 36 7 4 Air conditioning Appearance Dimension Drawing 1 Indoor...

Page 19: ...Page 18 of 36 2 Outdoor...

Page 20: ...essor is interrupted the outdoor LEDs are used to indicate the troubles listed below Symbols for indicator light ON flashing OFF LED1 LED2 LED3 Troubles 1 Normal 2 Room temperature sensor short circui...

Page 21: ...pressor Pre heating condition 3 Voltage transformer in trouble 31 Key AD value converted failure 4 Current transformer in trouble 33 Room temperature sensor in trouble 5 IPM module protection 34 Indoo...

Page 22: ...Page 21 of 36 8 2 Parts List and Details 8 2 1 Outdoor 8 2 1 1 Parts 19 21 30 31 34 33 29 28 32 27 26 25 23 22 24 20 9 8 7 5 4 3 2 1 35 18 6 12 13 11 10 14 17 16 15...

Page 23: ...04863 STOP VALVE 1 17 1332842 STOP VALVE 1 18 K33AB0008 NOISE DEFENING COVER 1 19 1204841 COMPRESSORS BOX 1 20 1339309 COMPRESSORS 1 21 1204988 COMPRESSORS RUBBER 3 22 RZA 2 5304 003 XX 1 CLIP ASSY 1...

Page 24: ...Page 23 of 36 8 2 2 Indoor 8 2 2 1 Parts...

Page 25: ...010 XX 0 15 1202481 Magnet Components 3 RZA 0 2265 001 01 0 16 1338557 display panel 1 17 8007085 Vertical Wind Plate 1 18 8007109 Vertical Wind Plate 1 19 8007423 Care Net 1 20 8007481 Foam pieces 1...

Page 26: ...Clasp 7 Fixed scroll 56 8007384 Support Parts 1 Pipe Clamp 57 1308927 Cover 3 58 1335430 Support Parts 1 Electrical Line Plate Sponge 59 1333210 Fan Motor 1 60 1331818 Fan scroll Parts 1 Scroll Spong...

Page 27: ...nce characteristics of the sensor Thermistor1326150 Inner 1205710 Inner Coil 1326145 Outer 1201121 Outer coil Standard Resistance Characteristics Temp Center Temp Center Temp Center Temp Center 30 63...

Page 28: ...8 20 598 42 2 6744 92 0 5656 142 0 1594 7 19 644 43 2 5825 93 0 5501 143 0 1557 6 18 739 44 2 4942 94 0 5352 144 0 1522 5 17 881 45 2 4093 95 0 5207 145 0 1487 4 17 068 46 2 3278 96 0 5066 146 0 1453...

Page 29: ...20 0 0977 11 323 11 21 0 1025 10 306 77 22 0 1074 9 291 4 23 0 1123 8 276 92 25 0 1221 7 263 29 26 0 127 6 250 44 27 0 1318 5 238 33 28 0 1367 4 226 91 30 0 1465 3 216 13 31 0 1514 2 205 95 33 0 1611...

Page 30: ...4 45 386 133 0 6494 35 43 703 138 0 6738 36 42 087 142 0 6934 37 40 536 147 0 7178 38 39 047 152 0 7422 39 37 616 157 0 7666 40 36 24 162 0 791 41 34 919 167 0 8154 42 33 648 172 0 8398 43 32 426 178...

Page 31: ...78 8 9078 443 2 1631 79 8 577 453 2 2119 80 8 2577 462 2 2559 81 7 9495 472 2 3047 82 7 652 482 2 3535 83 7 3649 492 2 4023 84 7 0878 501 2 4463 85 6 8204 511 2 4951 86 6 5623 521 2 5439 87 6 3133 531...

Page 32: ...08 2 7211 731 3 5693 109 2 6103 740 3 6133 110 2 5036 748 3 6523 111 2 4009 757 3 6963 112 2 3021 765 3 7354 113 2 207 773 3 7744 114 2 1155 781 3 8135 115 2 0276 789 3 8525 116 1 943 796 3 8867 117 1...

Page 33: ...rol board fault and replace it no yes Normal protection action no Unexpected phenomenon yes Outdoor control board fault Fault self test code 4 Evaporation overload evaporator with high temperature yes...

Page 34: ...n terminal block of outdoor unit Is there power output between 1 and 2 on terminal block of indoor unit Indoor Main Relay RY01 has output no no no no no Indoor control board fault and replace it yes C...

Page 35: ...he fan fault and replace it yes Fault self test code11 Brightness sensor fault The cable between control board and display board is bad no Indoor control board fault and replace it Display board failu...

Page 36: ...No Load Failure Compressor is running no Outdoor filter substrate failure and replace it IPM fault and replace it Is the voltage between P and N of the IPM normal no yes yes Is there voltage output b...

Page 37: ...nutes and is compressor running no yes Check outdoor unit air and the installation of IPM and radiator working closely Then ensure that IPM radiator is cooling Is the IPM radiator hotter Fault self te...

Reviews: