Page 20 of 36
21
×
★
★
With the drive module communication failure
22
23
Ο
×
Ο
DC compressor out of step
24
Ο
Ο
×
DC compressor fails to start
25
Ο
Ο
★
DC Fan Trouble
26
Ο
★
Ο
Outdoor DC compressor heating state
8.1.3
Indication by the indoor unit (on)
Fault code
Power
Running
Efficient
Fault code
Power
Running
Efficient
0
★
★
★
or
×
20
1
Ο
★
★
31
×
★
Ο
2
Ο
★
×
33
★
Ο
Ο
4
★
Ο
★
34
×
Ο
Ο
5
★
Ο
×
35
6
×
Ο
×
36
Ο
★
Ο
37
Ο
×
Ο
8
★
×
Ο
38
Ο
Ο
×
9
×
×
Ο
39
Ο
Ο
★
10 40
Ο
Ο
Ο
11
Ο
×
×
13
Ο
×
★
14
★
★
Ο
15
×
Ο
★
8.1.4
Indication by the indoor unit, Press the high power for 4 times in 10 seconds
and the trouble codes listed below will be displayed as follows:
0
No trouble
20 Outdoor DC fan failure
1 Outdoor coil temperature sensor in
trouble
21 Outdoor cooling coil anti-overload protection
2
Compressor temperature sensor in trouble
22 Compressor Pre-heating condition
3
Voltage transformer in trouble
31 Key AD value converted failure
4
Current transformer in trouble
33 Room temperature sensor in trouble
5 IPM
module
protection
34 Indoor
coil temperature sensor in trouble
6
Over and under-voltage control
35
7
Communication trouble
36 Communication between the indoor and outdoor
in trouble
8
Current overload control
37 Indoor and wired remote communication failure
9
Maximum current control
38 Indoor EE Fault
10 4-way valve changeover abnormal
39 Indoor fan motor operation abnormal
11 Outdoor EEPROM in trouble
40 Grid protection alarm (cabinet type)
12 Compressor exhaust temperature too high
control
13 Outdoor ambient temperature sensor in
trouble
14 Compressor housing temperature control
15 IPM
module
protection
16 Anti-freeze or overload control
17
18 DC compressor fails to start
19 DC compressor out of step
Summary of Contents for 88FZBpC
Page 1: ...KFR 72LW 88FZBpC Maintenance manual Hisense Kelon Air Conditionning Co Ltd...
Page 4: ...Page 3 of 36 OUTLINES 2 1 INDOOR 2 2 OUTDOOR 2 3 REMOTE...
Page 14: ...Page 13 of 36 ELECTRICAL DATA 7 1 Electric Wiring Diagrams 7 1 1 Indoor 7...
Page 15: ...Page 14 of 36 7 1 2 Outdoor...
Page 16: ...Page 15 of 36 7 2 Refrigerant Flow Diagram 7 3 System pressure diagram...
Page 17: ...Page 16 of 36...
Page 18: ...Page 17 of 36 7 4 Air conditioning Appearance Dimension Drawing 1 Indoor...
Page 19: ...Page 18 of 36 2 Outdoor...