8.1 Trouble List
8.1.1
When the compressor is in operation, The 3 LED indicator lights on the
control panel of the outdoor unit indicates the causes of the restriction on the
compressor’s current operating frequency
Symbols for indicator light:
★
: ON
Ο
: flashing
×
: OFF
LED1 LED2 LED3
The cause of the restriction on the compressor’s current operating frequency
1
Ο
Ο
Ο
Normal frequency ascent and descent with no restriction on the frequency
2
×
×
★
Frequency descent or restriction on frequency ascent caused by over
current
3
×
★
★
Frequency descent or restriction on frequency ascent caused by
anti-freeze in cooling or overload control in heating
4
★
×
★
Frequency descent or restriction on frequency ascent caused by too high
compressor discharge temperature
5
×
★
×
Restriction on maximum operation operating frequency caused by too low
voltage on the supply circuit
6
★
★
★
Operating at a fixed frequency (when in a capacity measurement or forced
operation at a fixed frequency.)
7
×
★
Ο
Outdoor anti-overload protection Frequency descent or restriction on
frequency
8.1.2
When the compressor is interrupted, the outdoor LEDs are used to indicate
the troubles listed below:
Symbols for indicator light:
★
: ON
Ο
: flashing
×
: OFF
LED1 LED2 LED3
Troubles
1
×
×
×
Normal
2
×
×
★
Room temperature sensor short-circuited, open circuited or the
corresponding test circuit in trouble
3
×
★
×
Indoor heat exchanger temperature sensor short-circuited, open circuited
or the corresponding test circuit in trouble
4
★
×
×
Compressor temperature sensor short-circuited, open circuited or the
corresponding test circuit in trouble
5
★
×
★
Outdoor heat exchanger temperature sensor short-circuited, open
circuited or the corresponding test circuit in trouble
6
★
★
×
Outdoor atmosphere temperature sensor short-circuited, open circuited
or the corresponding test circuit in trouble
7
Ο
★
×
CT (mutual inductance coil) short circuit, open circuit or detection
circuit fault
8
Ο
×
★
Outdoor voltage detection circuit fault
9
×
×
Ο
Signal communication abnormal (indoor – outdoor)
10
×
Ο
×
Power module (IPM)protection
11
★
Ο
★
Maximum
current
control
12
★
Ο
×
Current overload control
13
×
Ο
★
Compressor discharge temperature too high
14
★
★
Ο
Over and under-voltage control
15
★
Ο
Ο
Outdoor ambient temperature protection (only KFR-2820GW/BP)
16
17
Ο
★
★
Refrigerant leak (not yet available)
18
×
★
Ο
Compressor housing temperature too high
19
★
★
★
Outdoor memory in trouble
20
×
Ο
Ο
Indoor fan motor in trouble
Summary of Contents for 88FZBpC
Page 1: ...KFR 72LW 88FZBpC Maintenance manual Hisense Kelon Air Conditionning Co Ltd...
Page 4: ...Page 3 of 36 OUTLINES 2 1 INDOOR 2 2 OUTDOOR 2 3 REMOTE...
Page 14: ...Page 13 of 36 ELECTRICAL DATA 7 1 Electric Wiring Diagrams 7 1 1 Indoor 7...
Page 15: ...Page 14 of 36 7 1 2 Outdoor...
Page 16: ...Page 15 of 36 7 2 Refrigerant Flow Diagram 7 3 System pressure diagram...
Page 17: ...Page 16 of 36...
Page 18: ...Page 17 of 36 7 4 Air conditioning Appearance Dimension Drawing 1 Indoor...
Page 19: ...Page 18 of 36 2 Outdoor...