Hisense 88FZBpC Maintenance Manual Download Page 26

 

Page 25 of 37 

39 

1335565 

Seal plate parts 

Middle  Sponge 

40 8005554 

Electrical 

lid 

 

41 1326150 

Temperature 

device 

Temperature 

42 1318746 

Clamp 

1  Fixed 

Temperature 

Sensor 

43 1341826 

Transformers 

 

44 1201073 

TERMINAL 

PANEL 

 

45 1202889 

Fan 

Capacitor 

 

 

46 1356020 

Control 

Board 

 

47 

1331981 

Electric Box Components 

 

48 

8005556 

Support Parts 

Pipe Clamp 

49 

8005555 

Support Parts 

Support Box 

50 8006879 

Water 

tray 

 

51 1227302 

Drain 

 

52 

1205710 

Coil temperature sensor 

Coil 

53  

Evaporator 

Components 1 

 

54 

1337534 

Side components 

Side+Support Parts 

55 1205320 

Clasp 

Fixed 

scroll 

56 

8007384 

Support Parts 

Pipe Clamp 

57 1308927 

Cover 

 

58 1335430 

Support 

Parts 

1 Electrical Line Plate+Sponge 

59 1333210 

Fan 

Motor 

 

60 

1331818 

Fan scroll Parts 

Sponge 

61 1332202 

Centrifugal 

fan 

Green 

62 

8005548 

Deflector 

Inlet mask ring 

63 8005549 

Rail 

Right 

rail 

64 

8007382 

Filter Parts 

Light green 

65 

1339652 

Support Parts 

Left rail+Clamp 

66 8007104 

Sleeve 

 

67 8007107 

Support 

Parts 

 

68 8007110 

Vertical 

Wind 

Plate 

 

69 8007092 

Vertical 

Wind 

Plate 

 

70 8007090 

Inlet 

 

71 8007423 

Care 

Net 

 

72 8005217 

Base 

 

73 1339010 

Mounting 

plate 

parts 

 

74 8007424 

Care 

Net 

 

75 8007089 

Inlet 

 

76 8007091 

Vertical 

Wind 

Plate 

 

77 8007099 

Vertical 

Wind 

Plate 

 

78 8007088 

Bottom 

Panel 

 

79 8007087 

Bottom 

Panel 

 

80 1335573 

Panel 

components 

 

Summary of Contents for 88FZBpC

Page 1: ...KFR 72LW 88FZBpC Maintenance manual Hisense Kelon Air Conditionning Co Ltd...

Page 2: ...ment 7 5 2 Cooling run mode 19 5 3 Heating run mode 10 5 4 Dehumidifying mode 11 5 5 Air blowing mode 11 5 6 Dual mode 12 ELECTRICAL DATA 13 6 1 Electric Wiring Diagrams 13 6 2 Refrigerant Flow Diagra...

Page 3: ...Page 2 of 36 MODEL AND BRAND 1 1 Model KFR 60LW 88FZBpC 1 2 Marketing Trademark Hisense Trademarks 1 3 Short Selling Frequency And Energy Saving...

Page 4: ...Page 3 of 36 OUTLINES 2 1 INDOOR 2 2 OUTDOOR 2 3 REMOTE...

Page 5: ...Various models are complete and can realize various functions 3 1 2 Touch screen Through the touch screen can intelligently adjust various refrigeration heating and other functions as well as wind sp...

Page 6: ...with the large area of condenser and evaporator So air conditioner could run stable and reliable and energy efficient 3 2 3 Structural features Indoor structural elements is a new design Panels The u...

Page 7: ...ing frequency range Minimum Max Hz 25 105 Rated Heating Capacity Rated input power of low temperature heating kW 6 5 2 80 Rated Input Current Maximum Input Current A 11 4 20 0 Maximum Input Power kW 4...

Page 8: ...lay CPU receiving the signal from the indoor control board 6 1 4 Key Operation 6 1 4 1 Switch Key ON or OFF 6 1 4 2 Mode Key Switching mode cycle 6 1 4 3 Speed Key Switching wind speed loop 6 1 4 4 Te...

Page 9: ...uring the time of sleep mode the set temperature will change automatically The air conditioner will turn off and cancel the sleep function after the sleep function works for 8 hours 6 1 8 High efficie...

Page 10: ...thods see the corresponding mode 6 1 15 4 If shut down when the left throttle or intermediate damper in positioning uninterruptible power shutdown the leaves should be restored to the shutdown positio...

Page 11: ...en fixed and swept according to the remote The left right throttle is targeted to the minimum position in cold air prevention mode 6 3 1 2 The blades of the top throttle control The top throttle is fi...

Page 12: ...ange from cooling to heating it needs an interval of 50 seconds for the 4 way valve to change over from being interrupted to being electrified 6 3 6 Auxiliary Heating The unit automatically starts Aux...

Page 13: ...age 12 of 36 6 6 Dual mode 6 6 1 Comfort mode is separated cooling comfort mode and heating comfort mode 6 6 2 Energy saving mode is separated cooling energy saving mode and heating energy saving mode...

Page 14: ...Page 13 of 36 ELECTRICAL DATA 7 1 Electric Wiring Diagrams 7 1 1 Indoor 7...

Page 15: ...Page 14 of 36 7 1 2 Outdoor...

Page 16: ...Page 15 of 36 7 2 Refrigerant Flow Diagram 7 3 System pressure diagram...

Page 17: ...Page 16 of 36...

Page 18: ...Page 17 of 36 7 4 Air conditioning Appearance Dimension Drawing 1 Indoor...

Page 19: ...Page 18 of 36 2 Outdoor...

Page 20: ...essor is interrupted the outdoor LEDs are used to indicate the troubles listed below Symbols for indicator light ON flashing OFF LED1 LED2 LED3 Troubles 1 Normal 2 Room temperature sensor short circui...

Page 21: ...pressor Pre heating condition 3 Voltage transformer in trouble 31 Key AD value converted failure 4 Current transformer in trouble 33 Room temperature sensor in trouble 5 IPM module protection 34 Indoo...

Page 22: ...Page 21 of 36 8 2 Parts List and Details 8 2 1 Outdoor 8 2 1 1 Parts 19 21 30 31 34 33 29 28 32 27 26 25 23 22 24 20 9 8 7 5 4 3 2 1 35 18 6 12 13 11 10 14 17 16 15...

Page 23: ...04863 STOP VALVE 1 17 1332842 STOP VALVE 1 18 K33AB0008 NOISE DEFENING COVER 1 19 1204841 COMPRESSORS BOX 1 20 1339309 COMPRESSORS 1 21 1204988 COMPRESSORS RUBBER 3 22 RZA 2 5304 003 XX 1 CLIP ASSY 1...

Page 24: ...Page 23 of 36 8 2 2 Indoor 8 2 2 1 Parts...

Page 25: ...010 XX 0 15 1202481 Magnet Components 3 RZA 0 2265 001 01 0 16 1338557 display panel 1 17 8007085 Vertical Wind Plate 1 18 8007109 Vertical Wind Plate 1 19 8007423 Care Net 1 20 8007481 Foam pieces 1...

Page 26: ...Clasp 7 Fixed scroll 56 8007384 Support Parts 1 Pipe Clamp 57 1308927 Cover 3 58 1335430 Support Parts 1 Electrical Line Plate Sponge 59 1333210 Fan Motor 1 60 1331818 Fan scroll Parts 1 Scroll Spong...

Page 27: ...nce characteristics of the sensor Thermistor1326150 Inner 1205710 Inner Coil 1326145 Outer 1201121 Outer coil Standard Resistance Characteristics Temp Center Temp Center Temp Center Temp Center 30 63...

Page 28: ...8 20 598 42 2 6744 92 0 5656 142 0 1594 7 19 644 43 2 5825 93 0 5501 143 0 1557 6 18 739 44 2 4942 94 0 5352 144 0 1522 5 17 881 45 2 4093 95 0 5207 145 0 1487 4 17 068 46 2 3278 96 0 5066 146 0 1453...

Page 29: ...20 0 0977 11 323 11 21 0 1025 10 306 77 22 0 1074 9 291 4 23 0 1123 8 276 92 25 0 1221 7 263 29 26 0 127 6 250 44 27 0 1318 5 238 33 28 0 1367 4 226 91 30 0 1465 3 216 13 31 0 1514 2 205 95 33 0 1611...

Page 30: ...4 45 386 133 0 6494 35 43 703 138 0 6738 36 42 087 142 0 6934 37 40 536 147 0 7178 38 39 047 152 0 7422 39 37 616 157 0 7666 40 36 24 162 0 791 41 34 919 167 0 8154 42 33 648 172 0 8398 43 32 426 178...

Page 31: ...78 8 9078 443 2 1631 79 8 577 453 2 2119 80 8 2577 462 2 2559 81 7 9495 472 2 3047 82 7 652 482 2 3535 83 7 3649 492 2 4023 84 7 0878 501 2 4463 85 6 8204 511 2 4951 86 6 5623 521 2 5439 87 6 3133 531...

Page 32: ...08 2 7211 731 3 5693 109 2 6103 740 3 6133 110 2 5036 748 3 6523 111 2 4009 757 3 6963 112 2 3021 765 3 7354 113 2 207 773 3 7744 114 2 1155 781 3 8135 115 2 0276 789 3 8525 116 1 943 796 3 8867 117 1...

Page 33: ...rol board fault and replace it no yes Normal protection action no Unexpected phenomenon yes Outdoor control board fault Fault self test code 4 Evaporation overload evaporator with high temperature yes...

Page 34: ...n terminal block of outdoor unit Is there power output between 1 and 2 on terminal block of indoor unit Indoor Main Relay RY01 has output no no no no no Indoor control board fault and replace it yes C...

Page 35: ...he fan fault and replace it yes Fault self test code11 Brightness sensor fault The cable between control board and display board is bad no Indoor control board fault and replace it Display board failu...

Page 36: ...No Load Failure Compressor is running no Outdoor filter substrate failure and replace it IPM fault and replace it Is the voltage between P and N of the IPM normal no yes yes Is there voltage output b...

Page 37: ...nutes and is compressor running no yes Check outdoor unit air and the installation of IPM and radiator working closely Then ensure that IPM radiator is cooling Is the IPM radiator hotter Fault self te...