The unit has two ways to turn ON/OFF heating functions.
SF14: A/C On/Off way 1.) remote 2.) keyboard
A/C Switch:
SF14 set to “keyboard”(factory default setting). Then the A/C switch could not control the unit
any more, wired remote control will take over control the unit .
If SF14 set = “remote”. Keyboard can not be used to turn On/Off the heating and no heating
timezone On/Off function.
B1-B2 switch is activated to turn On/Off the unit.
When the A/C switch B1-B2 is bridged, the unit’s heating function is
activated. An external signal like a timer or thermostat, etc could be
connected to B1-B2 to activate or deactivate the unit’s heating function.
This external signal must be voltage free.
Case 1 : Install a manual switch inside the house to switch on/off heating.
Case 2: Install a timer switch inside the house to switch on/off heating automatically
Note
This is a potential free input contact only. DO NOT PUT 230VAC INTO THIS CONTACT
Electrical Connections