Appendix
QPE 8600
6 - 8
QPSK-receiver
Cause:
Something is wrong with the ftp-client.
Solution:
Change the device and contact one of our service centers.
Message:
General fault module x.
Cause:
Unknown.
Solution:
Change the device and contact one of our service centers.
Message:
General hardware failure.
Cause:
Maybe the device fails to access the EEPROM
OR The EEPROM checksum is not correct
OR the EEPROM data have changed.
OR The module has a wrong identification number (that means that the
hardware configuration is incorrect)
OR the adjustment bytes are incorrect.
Solution:
Change the device and contact one of our service centers.
Message:
I2C-bus blocked.
Cause:
Communication problem.
Solution:
Switch off the installation and interrupt the power supply for a few
seconds.
OR Restore the factory settings (SETUP menu) and reconfigure the
device.
Message:
Incorrect mail settings.
Cause:
Unknown.
Solution:
Check the mail settings.
Message:
Invalid module settings.
Cause:
Invalid settings.
Solution:
Check the module settings.
Message:
Modulator failure.
Cause:
Connection problem.
Solution:
Check if the specified connections are provided on the slide-in places
for the options (e.g. after removal of an option)
OR Change the device.
Message:
No battery found.
Cause:
Connection problem.
Solution:
Replace the battery.
Message:
No submodule found.
Cause:
Connection problem.
Solution:
Check the connection to the submodule.