Appendix
QPE 8600
6 - 6
QPSK-receiver
Message:
27 MHz failure.
Cause:
Unknown.
Solution:
Change the device and contact one of our service centers.
Message:
Amplifier A current overload.
Cause:
The hybrid is defect.
Solution:
Change the device and contact one of our service centers.
Message:
Amplifier B current overload.
Cause:
The hybrid is defect.
Solution:
Change the device and contact one of our service centers.
Message:
Battery empty - Data lost.
Cause:
The lifetime of the battery has expired.
Solution:
Replace the battery.
Message:
Battery has low voltage, replace.
Cause:
The lifetime of the battery has expired.
Solution:
Replace the battery.
Message:
Communication problem.
Cause:
Unknown.
Solution:
Interrupt the power supply for a few seconds.
OR Restore the factory settings in the SETUP menu and reconfigure
the device.
Message:
Current overload module x.
Cause:
Unknown.
Solution:
Change the device and contact one of our service centers.
Message:
DHCP failed _ Network disabled.
Cause:
DHCP access failure.
Solution:
Check the DHCP server in the network. If the DHCP server is out of
order, you can try entering a valid IP address manually. If the problem
cannot be solved this way, contact one of our service centers.
Message:
DHCP failure (no valid server found).
Cause:
DHCP access failure.
Solution:
Check the DHCP server in the network. If the DHCP server is out of
order, you can try entering a valid IP address manually. If the problem
cannot be solved this way, contact one of our service centers.