Help with problems
LED indications
Failure
Repair
LC-display is dark
- Press any key
- Check the power supply
- Check the mains fuse
- Change the QPSK-receiver.
LED ”
f
” lights up red
- An alarm was triggered. Check in the history which
alarm is active. Solve the problem or change the
alarm threshold.
- An existing Ethernet connection was interrupted.
Restore the connection.
- Change the QPSK-receiver.
LED ”OUT” is dark
- Check the input signal (frequency,
level, C/N etc.) at the monitoring output
- Check following settings:
- Input frequency
- Symbol rate
- LNC
- LNC 22 kHz
- PLL source
- PID
- Protocol
- Restore the factory settings with “Preset” and
reconfigure the device.
LED ”OUT” is dark
nput signal locked
PLL status: unlocked
- Check the following settings:
- PID
- Restore the factory settings with “Preset” and
reconfigure the device.
NOTE
:
Error messages, which are inserted on the LC-display, are listed in
the appendix.
Maintenance
QPE 8600
4 - 4
QPSK-receiver