background image

Part Numbers 

© Hirschmann ECS, 2006; PRS 80 Wind Speed Rev.C  05/23/06 

190184_C 

17

 

 

 
 
 
 
 
 

 

 

031-300-050-672 ANTENNA , 918 
MHz MAGNETICBASE 13' long wire 

031-300-050-671 ANTENNA, 918 MHz FOR 
TRS05ASSEMBLY 060-576 WHIP ELEMENT 

031-300-060-607 SENSOR ASSY, 
WINDSPEED RADIO

 

MTG PLATE SPREAD 

SPECTRUM L-B 

031-300-050-688 ANTENNA, 
918 MHz RCL 90°

031-300-060-584 CONSOLE, PRS80 RADIO 
RECEIVER LOAD/A2B/WIND/ANGLE 20AWG PWR 

Summary of Contents for PRS 80 Wind Speed

Page 1: ...www hirschmann com P N 031 300 190 184 REV C 05 23 06 PRS 80 Wind Speed OPERATOR S SERVICE MANUAL...

Page 2: ......

Page 3: ...tion which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Hirschman...

Page 4: ...PRS 80 Wind Speed Operator s Service Manual Hirschmann ECS 2006 PRS 80 Wind Speed Rev C 05 23 06 190184_C 4...

Page 5: ...3 5 SYSTEM OPERATION 4 5 1 MENU S 5 5 2 MENU SELECTION INSTRUCTIONS 5 5 3 LIMITS 5 6 INSTALLATION AND SETUP 6 6 1 CONSOLE MOUNTING 6 6 2 WIRING 7 6 3 ADDING SENSORS 8 6 4 WIND SPEED SENSOR 9 7 SERVICE...

Page 6: ......

Page 7: ...se damage to equipment and personal injury This device is not and must not be a substitute for good sound operator judgment experience and use of accepted safe crane operating procedures The responsib...

Page 8: ...he operator s field of vision 4 1 1 Liquid Crystal Display The Liquid Crystal Display LCD used in the Hirschmann ECS PRS 80 console is a wide temperature range graphic display with transflective chara...

Page 9: ...nsole 1 LCD 2 Clear button 3 Select button 4 Up Button 5 Down Button Button SCROLL UP Use this button to increase values or to scroll up Changes which sensors are displayed and how each is displayed B...

Page 10: ...ible range 5 SYSTEM OPERATION When switching on crane ignition switch the system starts with an automatic test of the system of lamps and audible alarm During the test the LC display shows the console...

Page 11: ...ons From the operating screen press to enter the menu selection Use the up and down to scroll through and high light your selection then press to make the selection 5 3 Limits The system sets the defa...

Page 12: ...cation that is in line of site of the sensor and within reach of the operator Securely attach the base of the mounting apparatus onto a solid surface The console has a mount that allows the console to...

Page 13: ...nn ECS 2006 PRS 80 Wind Speed Rev C 05 23 06 190184_C 7 6 2 Wiring The wiring at the console connection is Pin Description 1 Power 10 30VDC 2 Ground 3 Lockout NO 2 amp max 4 Lockout NC 2 amp max 5 Loc...

Page 14: ...s are installed Sensor status screen Choose the sensor that you wish to install and follow the onscreen instructions which will ask you to remove the paper tap insulating the battery contact or instal...

Page 15: ...NG INSTRUCTIONS PRIOR TO WELDING ON BOOM The mounting pole is affixed to the boom tip at your discretion so that the anemometer sensor is mounted approximately a foot higher than the boom sheaves and...

Page 16: ...y must be replaced immediately to prevent ingress of water and damage to the internal circuitry Other than correcting the problems identified in the Malfunctions Table and replacing faulty mechanical...

Page 17: ...example both the load and the A2B 1 are in error Only the sensors that communication error are shown 7 2 Diagnostics There are several diagnostics screens that can be accessed thru the display Howeve...

Page 18: ...pressed the corresponding button on the console will invert Press each button one at a time When finished press and hold C 7 2 3 To Test the outputs Press Menu SETUP DIAGNOSTICS OUTPUTS Arrow to sele...

Page 19: ...7 4 Troubleshooting Moisture The receiver contains electronic components and has an IP65 protection rating These electronic components cannot be designed to withstand exposure to moisture over a long...

Page 20: ...or Faulty sensor Verify which sensor is causing the error by looking at the icons on the communication error screen Verify that the LED on the sensor is blinking Communication error Poor reception Ver...

Page 21: ...on the transmitter for nicks or other damages that may prevent the gasket from sealing If it appears to be damaged a replacement gasket should be installed Install 4 fresh batteries into the proper l...

Page 22: ...6 9 PART NUMBERS CONSOLE 031 300 060 584 PRS80 Console Item Part number Qty Description 1 031 300 060 382 1 0 Mounting Arm W 1 Ball 2 024 000 100 095 1 0 Membrane Element 3 031 300 050 223 1 0 Fuse 2...

Page 23: ...ENNA 918 MHz MAGNETICBASE 13 long wire 031 300 050 671 ANTENNA 918 MHz FOR TRS05ASSEMBLY 060 576 WHIP ELEMENT 031 300 060 607 SENSOR ASSY WINDSPEED RADIO MTG PLATE SPREAD SPECTRUM L B 031 300 050 688...

Reviews: