PRS 80 Wind Speed Operator’s/Service Manual
© Hirschmann ECS, 2006; PRS 80 Wind Speed Rev.C 05/23/06
190184_C
4
Button "C"
•
Generally used to back out of a selection and return to the previous
screen.
•
While pushing this button, the control lever lockout function of the
system can be deactivated.
•
Accesses the Tare function
Since button C can deactivate the lockout function of the system, the following instructions
must be obeyed:
•
The by-pass function shall be used with discretion, as unwarranted use of it to override
the control lever lockout system can result in harm to the crane and danger to property
and persons.
•
Never use the by-pass function to either overload or operate the crane in a non-
permissible range.
5 SYSTEM
OPERATION
When switching on crane ignition switch, the system starts with an automatic test of the system, of
lamps and audible alarm. During the test, the LC display shows the console and system software
version. After the testing is complete, the main operating screen will be displayed.
If the wind speed requires setup (installed), refer to the Installation and Setup Section 6.3 sensors
procedure allows the operator to input the sensors being used and the limits for the sensors. The
operator must complete the setup procedure for each sensor.
The speed can be shown in miles per hour, or kilometers per hour.
The % of limit is shown at the bottom.
The peak will be the highest wind speed recorded since the system was started. When the system is
turned off the peak value will be reset. The peak value can also be reset by pressing the
button.
PEAK VALUE
CURRENT WIND SPEED
UNITS
% of LIMIT